onoae

Honda HD350 Ultrasonic Level Meter

Honda HD350 Ultrasonic Level Meter transmitted from the sensor are reflected back from the measured object

Loading...

Description

Honda HD350 Ultrasonic Level Meter transmitted from the sensor are reflected back from the measured object, and the distance is calculated based on the echo return time. This makes it possible to perform operations such as measuring the liquid level inside a tank or monitoring the remaining amount of materials in a tank.

Honda HD350 Ultrasonic Level Meter Features

Honda HD350 Ultrasonic Level Meter is a compact, lightweight level meter which includes sensor and display in one unit. Graphical display shows real time wave form in A-mode and it is useful for maintenance. Mask function can avoid noise interference.

Features

  • For screen mode can be selected
  • Large display is adopted for HD353-A (Display size : 50 x 25mm, 49% larger than HD350-A)
  • Mask function
    • Unnecessary signal can be eliminated from the received signal by manually.
    • Echo signal from existing structure positioned between sensor and target cause interference.
    • Mask function removes these unnecessary echo effectively.
  • Interface
    • Three interface methods are prepared for remote operation.
      • RS-485 (MODBUS protocol)
      • 4-20 mA current output
      • Contact points (relay output)
  • Low-cost DSP level meter
  • Graphic LCD display shows the A-mode waveform
  • Wide measurement range, from 0.3 to 10 m
  • When performing measurements, masking can be applied to objects positioned between the sensor and target
  • Remote operation is enabled with RS-485 ( MODBUS® protocol ), 4 to 20 mA current output, and alarm output contact points

Applications

  • Measurement of liquid, powder level in a tank
  • Measurement of water levels in lakes, ponds or rivers

Specifications

Model No. HD350-A HD353-A
Number of channels 1
Frequency 50kHz
Measurement target liquid / powder
Measurement distance range (1/2 for powder) 0.3 to 10m
Resolution Measurement 1mm
Display 1mm
Accuracy ±0.25%F.S.
(±2.5cm)
Data update cycle 0.5 sec
Sensor directive angle (beam angle) 14°(-6dB) / 10°(-3dB)
Power source Voltage 12 – 24 VDC ±10%
Power consumption 3 W
Display Graphic LCD
Display size 28.1 x 9.1mm 50 x 25mm
Output Alarm output 1 point each for upper/lower
(NPN open collector)
4-20 mA current Resolution: 12 bits
(Max. load 500Ω)
Interface RS-485 (Transmitting distance : max. 1200m)
Ambient operating temperature -20 to 70℃
Material PP (polypropylene)
Protection IP65 equivalent (without lid: IP20 equivalent)
Dimensions dia. 93 x 110mm
Cable length 10m
Weight 350g
Mounting screw G2 (PF2)

● Option: 30m cable

Do not use metal nut or metal flange. It may cause error on measurement.
* Please use nut or flange that made of plastic.