FCON CUBE MFC Series Mass Flow Controller

Fcon CUBE MFC Digital Mass flow controller 1000 series and control power supply are all-in-one compact flow control unit. It can be used by connecting the gas fitting and power outlet. The suppression of Flow surge (overshoot) at the start (Requires more than 30 seconds of the interval).

FCON CUBE MFC Series Mass Flow Controller is an ultra-compact, all-in-one digital gas mass flow controller featuring a high-visibility integrated digital display and direct local control interface. Engineered for space-constrained installations, benchtop testing, and portable laboratory systems, the CUBE MFC eliminates the need for separate external readout units or dedicated power/display modules. Powered by FCON’s high-precision thermal mass flow sensor and a fast-acting proportional solenoid valve, the CUBE MFC Series delivers standalone, plug-and-play mass flow metering and closed-loop regulation for a wide variety of industrial and laboratory gases.

Technical Overview & Operating Principle

The FCON CUBE MFC Series Mass Flow Controller operates using capillary thermal mass flow sensing combined with integrated digital signal processing and local display drive electronics.

A precision bypass splits a small portion of gas into a heated capillary sensor element. As the gas flows through the capillary, it transfers heat downstream.

Specifications

ParameterSpecification
Product SeriesFCON CUBE MFC Series
Focus Keyword TargetFCON CUBE MFC Series Mass Flow Controller
Measurement PrincipleCapillary Thermal Mass Flow Sensing
Target MediaClean, Dry Process & Inert Gases (N2, Air, Ar,O2,CO2,He,H2)
Flow Rate Range10 SCCM up to 20 SLM (Standard Liters per Minute)
Control Accuracy 1.0% Full Scale
Repeatability0.2% Full Scale
Response Time1.0 second to reach target setpoint
Operating Pressure Range0.05 MPa to  0.3 MPa differential pressure 0.5 MPa max inlet pressure)

Features

  • Integrated Digital Display & Control Panel: Built-in screen displays instantaneous flow rate, cumulative totalizer, and setpoint target with intuitive local pushbuttons.

  • Ultra-Compact “CUBE” Form Factor: All-in-one architecture integrates the sensor, proportional valve, control circuit, and display into a tiny footprint.

Applications

  • Benchtop Laboratory Experiments: Direct tabletop control of carrier and purge gases without needing external readout power supplies.

  • Portable Sampling Rigs & Analyzers: Field-deployable gas sampling equipment, environmental monitoring, and gas analyzer calibration systems.

  • Bioreactor & Fermentation Gas Delivery: Compact sparging control for lab-scale bio-reactors requiring local flow display and control.

  • Micro-Burner & Precision Flame Control: Tabletop glass-blowing, micro-soldering, and thermal process flame monitoring.

Related Products

Best FCON CUBE MFC Series Mass Flow Controller

Fcon CUBE MFC Digital Mass flow controller 1000 series and control power supply are all-in-one compact flow control unit. It can be used by connecting the gas fitting and power outlet.

Product Note:

No product notes available.

Loading...

Description

FCON CUBE MFC Series Mass Flow Controller

Fcon CUBE MFC Digital Mass flow controller 1000 series and control power supply are all-in-one compact flow control unit. It can be used by connecting the gas fitting and power outlet. The suppression of Flow surge (overshoot) at the start (Requires more than 30 seconds of the interval).

FCON CUBE MFC Series Mass Flow Controller is an ultra-compact, all-in-one digital gas mass flow controller featuring a high-visibility integrated digital display and direct local control interface. Engineered for space-constrained installations, benchtop testing, and portable laboratory systems, the CUBE MFC eliminates the need for separate external readout units or dedicated power/display modules. Powered by FCON’s high-precision thermal mass flow sensor and a fast-acting proportional solenoid valve, the CUBE MFC Series delivers standalone, plug-and-play mass flow metering and closed-loop regulation for a wide variety of industrial and laboratory gases.

Technical Overview & Operating Principle

The FCON CUBE MFC Series Mass Flow Controller operates using capillary thermal mass flow sensing combined with integrated digital signal processing and local display drive electronics.

A precision bypass splits a small portion of gas into a heated capillary sensor element. As the gas flows through the capillary, it transfers heat downstream.

Specifications

ParameterSpecification
Product SeriesFCON CUBE MFC Series
Focus Keyword TargetFCON CUBE MFC Series Mass Flow Controller
Measurement PrincipleCapillary Thermal Mass Flow Sensing
Target MediaClean, Dry Process & Inert Gases (N2, Air, Ar,O2,CO2,He,H2)
Flow Rate Range10 SCCM up to 20 SLM (Standard Liters per Minute)
Control Accuracy 1.0% Full Scale
Repeatability0.2% Full Scale
Response Time1.0 second to reach target setpoint
Operating Pressure Range0.05 MPa to  0.3 MPa differential pressure 0.5 MPa max inlet pressure)

Features

  • Integrated Digital Display & Control Panel: Built-in screen displays instantaneous flow rate, cumulative totalizer, and setpoint target with intuitive local pushbuttons.

  • Ultra-Compact “CUBE” Form Factor: All-in-one architecture integrates the sensor, proportional valve, control circuit, and display into a tiny footprint.

Applications

  • Benchtop Laboratory Experiments: Direct tabletop control of carrier and purge gases without needing external readout power supplies.

  • Portable Sampling Rigs & Analyzers: Field-deployable gas sampling equipment, environmental monitoring, and gas analyzer calibration systems.

  • Bioreactor & Fermentation Gas Delivery: Compact sparging control for lab-scale bio-reactors requiring local flow display and control.

  • Micro-Burner & Precision Flame Control: Tabletop glass-blowing, micro-soldering, and thermal process flame monitoring.