Gastec P-132-H Permeation Tube Methyl Chloride

Gastec P-132-H Permeation Tube Methyl Chloride generating calibration gas with a permeation tube with Concentration range 1.6 – 77 ppm. When housed inside a constant-temperature dynamic gas calibration generator (such as the Gastec PD-1B or standard laboratory calibration diluters), it releases a certified, micro-rate mass flow of pure methyl chloride through a fluoropolymer membrane into a controlled dilution air or nitrogen stream.

WARNING:

  1. Use only Gastec detector tube in a Gastec Pump.
  2. Do not interchange or use non-Gastec parts of components in Gastec’s detector tube and pump system.
  3. The use of non-Gastec parts of component in Gastec’s detector tube and pump system, or use of a non-Gastec detector tube with a Gastec pump, or use of a Gastec detector tube with a non-Gastec pump may result in property damage, serious bodily injury, and death, voids all warranties, and voids all performance and data accuracy guarantees.

Application of the tube:

Use this tube for detecting Hydrogen fluoride in the air or in industrial areas and for determining the environmental atmospheric condition.

Specifications

ParameterSpecification
ManufacturerGastec Corporation
Part Number / ModelP-132-H / P132H
Target Chemical VaporMethyl Chloride / Chloromethane ($text{CH}_3text{Cl}$)
Permeation MembraneFluoropolymer (FEP/Teflon) capillary reservoir
Certified Operating Temp$30.0^circtext{C to }40.0^circtext{C}$ (specified on individual calibration certificate)
Primary Output RangeGenerates $0.5text{ to }50.0text{ ppm}$ (dependent on carrier gas flow rate)
Expected Service Life6 to 12 months (determined by operating temperature and initial fill mass)
Compatible EquipmentGastec PD-1B / PD-1C Gas Generator series, standard dynamic gas diluters

Features

Concentration range 1.6 – 77 ppm

Applications

  • Chemical & Pharmaceutical Plant Safety: Calibrating photoionization (PID), flame ionization (FID), and gas chromatograph (GC) instruments used for workplace air monitoring in silicone synthesis, butyl rubber manufacturing, and chemical synthesis facilities.

  • Colorimetric Detector Tube Validation: Laboratory verification and accuracy auditing of Gastec Methyl Chloride detector tubes (such as Gastec 132 series).

  • Industrial Hygiene Audits: Generating low-ppm span standards to verify leak detection equipment and ambient monitoring alarms for toxic halogenated hydrocarbon vapors.

Downloads

Related Products

Gastec P-132-H Permeation Tube Methyl Chloride

Gastec P-132-H Permeation Tube Methyl Chloride generating calibration gas with a permeation tube with Concentration range 1.6 – 77 ppm

Product Note:

No product notes available.

Categories: ,

Loading...

Description

Gastec P-132-H Permeation Tube Methyl Chloride

Gastec P-132-H Permeation Tube Methyl Chloride generating calibration gas with a permeation tube with Concentration range 1.6 – 77 ppm. When housed inside a constant-temperature dynamic gas calibration generator (such as the Gastec PD-1B or standard laboratory calibration diluters), it releases a certified, micro-rate mass flow of pure methyl chloride through a fluoropolymer membrane into a controlled dilution air or nitrogen stream.

WARNING:

  1. Use only Gastec detector tube in a Gastec Pump.
  2. Do not interchange or use non-Gastec parts of components in Gastec’s detector tube and pump system.
  3. The use of non-Gastec parts of component in Gastec’s detector tube and pump system, or use of a non-Gastec detector tube with a Gastec pump, or use of a Gastec detector tube with a non-Gastec pump may result in property damage, serious bodily injury, and death, voids all warranties, and voids all performance and data accuracy guarantees.

Application of the tube:

Use this tube for detecting Hydrogen fluoride in the air or in industrial areas and for determining the environmental atmospheric condition.

Specifications

ParameterSpecification
ManufacturerGastec Corporation
Part Number / ModelP-132-H / P132H
Target Chemical VaporMethyl Chloride / Chloromethane ($text{CH}_3text{Cl}$)
Permeation MembraneFluoropolymer (FEP/Teflon) capillary reservoir
Certified Operating Temp$30.0^circtext{C to }40.0^circtext{C}$ (specified on individual calibration certificate)
Primary Output RangeGenerates $0.5text{ to }50.0text{ ppm}$ (dependent on carrier gas flow rate)
Expected Service Life6 to 12 months (determined by operating temperature and initial fill mass)
Compatible EquipmentGastec PD-1B / PD-1C Gas Generator series, standard dynamic gas diluters

Features

Concentration range 1.6 – 77 ppm

Applications

  • Chemical & Pharmaceutical Plant Safety: Calibrating photoionization (PID), flame ionization (FID), and gas chromatograph (GC) instruments used for workplace air monitoring in silicone synthesis, butyl rubber manufacturing, and chemical synthesis facilities.

  • Colorimetric Detector Tube Validation: Laboratory verification and accuracy auditing of Gastec Methyl Chloride detector tubes (such as Gastec 132 series).

  • Industrial Hygiene Audits: Generating low-ppm span standards to verify leak detection equipment and ambient monitoring alarms for toxic halogenated hydrocarbon vapors.