EGE Level Controller

EGE Level Controller PTFE and PEEK are here the preferred materials because they prevent adhesions. Opto-fill sensors with glass or PSU tips do not require a medium adjustment and are simply added to the tank. These sensors are also available as explosion-proof units in accordance with ATEX. Ultrasonic sensors, pressure controllers, or the capacitive high-temperature measuring probe KFA continuously monitor and log fill levels.

Core Operational Functions

  • Continuous Level Tracking: Provides real-time level evaluation using Time Domain Reflectometry (TDR guided microwave) or capacitive field detection, outputting linear 4-20 mA signals to PLCs and SCADA networks.

  • Point-Level & Limit Detection: Acts as high- or low-level limit switches (capacitive, conductive, or optoelectronic) to trigger immediate interlocks when fluids reach critical thresholds.

  • Pump & Valve Automation: Drives automated tank filling or emptying cycles using dual setpoints (hysteresis control) to start pumps at low level and stop them at high level.

  • Overfill & Dry-Run Protection: Prevents pump cavitation by shutting off feed systems when levels drop below minimum limits, while preventing tank spills by cutting inlet valves at maximum fill capacity.

  • Media-Specific Compensation: Filters out background buildup, foaming, or splashing on probe surfaces (especially in sticky liquids, pastes, or bulk powders) to prevent false switching.

Specifications

  • Capacitive level controllers are available for gases to -200 °C as well as hot glue-up to +230 °C.
  • PTFE and PEEK are here the preferred materials because they prevent adhesions.
  • Opto fill sensors with glass or PSU tips do not require a medium adjustment and are simply added to the tank.
  • These sensors are also available as explosion-proof units in accordance with ATEX.
  • Ultrasonic sensors, pressure controllers, or the capacitive high-temperature measuring probe KFA continuously monitor and log fill levels.

Features

  • for level monitorring -230 … +230 oC
  • steam proof at a pressure of up to 30 bar
  • for hot motor oil
  • for liquid nitrogen
  • for chemically aggressive media

Applications

  • Microwave meter
  • Microwave level controllers
  • Capacitive sensors
  • Medium adjustment for capacitive sensors
  • Laboratory adjustment
  • Opto-sensors UF../UR..
  • Conductive level controller
  • Sensors for explosion hazardous areas

Downloads

Datasheet : EGE Level Controller

Related Products

Best EGE Level Controller

EGE Level Controller is here the preferred material because they prevent adhesions. Opto-fill sensors with glass or PSU tips do not require a medium adjustment and are simply added to the tank.

Product Note:

No product notes available.

Loading...

Description

EGE Level Controller

EGE Level Controller PTFE and PEEK are here the preferred materials because they prevent adhesions. Opto-fill sensors with glass or PSU tips do not require a medium adjustment and are simply added to the tank. These sensors are also available as explosion-proof units in accordance with ATEX. Ultrasonic sensors, pressure controllers, or the capacitive high-temperature measuring probe KFA continuously monitor and log fill levels.

Core Operational Functions

  • Continuous Level Tracking: Provides real-time level evaluation using Time Domain Reflectometry (TDR guided microwave) or capacitive field detection, outputting linear 4-20 mA signals to PLCs and SCADA networks.

  • Point-Level & Limit Detection: Acts as high- or low-level limit switches (capacitive, conductive, or optoelectronic) to trigger immediate interlocks when fluids reach critical thresholds.

  • Pump & Valve Automation: Drives automated tank filling or emptying cycles using dual setpoints (hysteresis control) to start pumps at low level and stop them at high level.

  • Overfill & Dry-Run Protection: Prevents pump cavitation by shutting off feed systems when levels drop below minimum limits, while preventing tank spills by cutting inlet valves at maximum fill capacity.

  • Media-Specific Compensation: Filters out background buildup, foaming, or splashing on probe surfaces (especially in sticky liquids, pastes, or bulk powders) to prevent false switching.

Specifications

  • Capacitive level controllers are available for gases to -200 °C as well as hot glue-up to +230 °C.
  • PTFE and PEEK are here the preferred materials because they prevent adhesions.
  • Opto fill sensors with glass or PSU tips do not require a medium adjustment and are simply added to the tank.
  • These sensors are also available as explosion-proof units in accordance with ATEX.
  • Ultrasonic sensors, pressure controllers, or the capacitive high-temperature measuring probe KFA continuously monitor and log fill levels.

Features

  • for level monitorring -230 … +230 oC
  • steam proof at a pressure of up to 30 bar
  • for hot motor oil
  • for liquid nitrogen
  • for chemically aggressive media

Applications

  • Microwave meter
  • Microwave level controllers
  • Capacitive sensors
  • Medium adjustment for capacitive sensors
  • Laboratory adjustment
  • Opto-sensors UF../UR..
  • Conductive level controller
  • Sensors for explosion hazardous areas

Downloads