Flowma LMP633-NSN-H Submersible Level Transmitter

Flowma LMP633-NSN-H Submersible Level Transmitter is designed for dealing with the most severe demanding level measurement conditions. It is the optimal choice to satisfy all of high demand level measuring applications.

Flowma LMP633-NSN-H (LEEG LMP633 series OEM variant) is a heavy-duty, anti-corrosive submersible hydrostatic level transmitter engineered for continuous liquid level measurement in highly aggressive chemicals, wastewater, and saline environments.

Unlike standard stainless steel pressure probes, the -NSN-H configuration utilizes a high-purity PVDF (Polyvinylidene Fluoride) or PTFE probe housing, a ceramic capacitive diaphragmatic sensor element, and a specialized chemical-resistant submersible cable to prevent material degradation.

Core Operational Functions

  • Hydrostatic Pressure Measurement: Operates on the principle that static liquid head pressure is directly proportional to liquid height.

  • Corrosive Media Sensing: The dry ceramic capacitive sensor diaphragm (99.6%Al_2 O_3) contacts the liquid directly without intermediate oil filling, providing high mechanical strength and immunity to strong acids and bases.

  • Barometric Vented Line Compensation: The submersible cable incorporates an internal capillary vent tube to reference ambient atmospheric pressure changes, ensuring precise net level tracking regardless of weather or vessel closure.

  • Signal Conditioned Transmission: Integrates internal signal processing electronics to output a linear 4–20 mA current loop (2-wire system) or RS-485 Modbus RTU interface for long-distance PLC/SCADA transmission.

Specifications

ParameterSpecification
Measuring PrincipleCeramic Capacitive Hydrostatic Pressure
Measuring RangeCustom configurable from $0text{–}1text{ mH}_2text{O}$ up to $0text{–}100text{ mH}_2text{O}$
Accuracy$pm 0.2%text{ FS}$ or $pm 0.5%text{ FS}$
Housing MaterialPVDF (Polyvinylidene Fluoride) / PTFE wetted probe body
Diaphragm MaterialCeramic $99.6%text{ Al}_2text{O}_3$
Cable / Seal MaterialPTFE / FKM (Viton) or EPDM chemical seals
Output Options$4text{–}20text{ mA}$ (2-wire) or RS-485 Modbus-RTU
Power Supply$12text{ to }30text{ V DC}$
Operating Temperature-10°C to +70°C
Ingress RatingIP68 fully submersible sensor head

Features

Barometric Vented Cable & Protection

  • Atmospheric Reference Venting: Submersible cable features an integrated capillary air tube with a protective desiccant filter to compensate for atmospheric barometric pressure fluctuations.

  • Rugged Chemical Cable Sheathing: Cable outer jacket is constructed from chemically inert materials (PTFE / FKM seals) to prevent swelling, hardening, or cracking during long-term chemical immersion.

Applications

  • Chemical Storage & Dosing Tanks: Monitoring levels of concentrated hydrochloric acid ($text{HCl}$), sulfuric acid ($text{H}_2text{SO}_4$), sodium hypochlorite ($text{NaClO}$), and caustic soda ($text{NaOH}$).

  • Industrial Wastewater & Leachate: Submerged level tracking in acidic industrial effluent, mining runoff pits, and landfill leachate sumps.

  • Seawater & Desalination Plants: Continuous level monitoring in high-salinity brine tanks and marine intake wells where metallic probes suffer galvanic corrosion.

Related Products

Best Flowma LMP633-NSN-H Submersible Level Transmitter

Flowma LMP633-NSN-H Submersible Level Transmitter is designed for dealing with the most severe demanding level measurement conditions.

Product Note:

No product notes available.

Loading...

Description

Flowma LMP633-NSN-H Submersible Level Transmitter

Flowma LMP633-NSN-H Submersible Level Transmitter is designed for dealing with the most severe demanding level measurement conditions. It is the optimal choice to satisfy all of high demand level measuring applications.

Flowma LMP633-NSN-H (LEEG LMP633 series OEM variant) is a heavy-duty, anti-corrosive submersible hydrostatic level transmitter engineered for continuous liquid level measurement in highly aggressive chemicals, wastewater, and saline environments.

Unlike standard stainless steel pressure probes, the -NSN-H configuration utilizes a high-purity PVDF (Polyvinylidene Fluoride) or PTFE probe housing, a ceramic capacitive diaphragmatic sensor element, and a specialized chemical-resistant submersible cable to prevent material degradation.

Core Operational Functions

  • Hydrostatic Pressure Measurement: Operates on the principle that static liquid head pressure is directly proportional to liquid height.

  • Corrosive Media Sensing: The dry ceramic capacitive sensor diaphragm (99.6%Al_2 O_3) contacts the liquid directly without intermediate oil filling, providing high mechanical strength and immunity to strong acids and bases.

  • Barometric Vented Line Compensation: The submersible cable incorporates an internal capillary vent tube to reference ambient atmospheric pressure changes, ensuring precise net level tracking regardless of weather or vessel closure.

  • Signal Conditioned Transmission: Integrates internal signal processing electronics to output a linear 4–20 mA current loop (2-wire system) or RS-485 Modbus RTU interface for long-distance PLC/SCADA transmission.

Specifications

ParameterSpecification
Measuring PrincipleCeramic Capacitive Hydrostatic Pressure
Measuring RangeCustom configurable from $0text{–}1text{ mH}_2text{O}$ up to $0text{–}100text{ mH}_2text{O}$
Accuracy$pm 0.2%text{ FS}$ or $pm 0.5%text{ FS}$
Housing MaterialPVDF (Polyvinylidene Fluoride) / PTFE wetted probe body
Diaphragm MaterialCeramic $99.6%text{ Al}_2text{O}_3$
Cable / Seal MaterialPTFE / FKM (Viton) or EPDM chemical seals
Output Options$4text{–}20text{ mA}$ (2-wire) or RS-485 Modbus-RTU
Power Supply$12text{ to }30text{ V DC}$
Operating Temperature-10°C to +70°C
Ingress RatingIP68 fully submersible sensor head

Features

Barometric Vented Cable & Protection

  • Atmospheric Reference Venting: Submersible cable features an integrated capillary air tube with a protective desiccant filter to compensate for atmospheric barometric pressure fluctuations.

  • Rugged Chemical Cable Sheathing: Cable outer jacket is constructed from chemically inert materials (PTFE / FKM seals) to prevent swelling, hardening, or cracking during long-term chemical immersion.

Applications

  • Chemical Storage & Dosing Tanks: Monitoring levels of concentrated hydrochloric acid ($text{HCl}$), sulfuric acid ($text{H}_2text{SO}_4$), sodium hypochlorite ($text{NaClO}$), and caustic soda ($text{NaOH}$).

  • Industrial Wastewater & Leachate: Submerged level tracking in acidic industrial effluent, mining runoff pits, and landfill leachate sumps.

  • Seawater & Desalination Plants: Continuous level monitoring in high-salinity brine tanks and marine intake wells where metallic probes suffer galvanic corrosion.