Skip to main content

onoae

Gastec GSP-400FT Automatic Air Sampling Pump

Gastec GSP-400FT Automatic Air Sampling Pump

Product Note:

No product notes available.

Categories: , Tags: , ,

Description

Gastec GSP-400FT Automatic Air Sampling Pump

Gastec GSP-400FT Automatic Air Sampling Pump Gastec GSP-400FT Automatic Air Sampling Pump Flow volume of 50-1000mL/min can be set.

GASTEC Detector Tubes indicate concentrations directly by way of a calibrated scale printed on the tubes. At GASTEC, we endeavour to achieve highest quality detector tubes for analysing airborne gases/vapours, as well as pollutants in soil and water through our advanced state-of-the-art research and development. Through our efforts we have acquired a solid reputation among our customers in virtually all sectors of industry, commerce and society. Tubes are now available for more than 500 different applications.

Function

  • Mass Flow Controlled Sample Collection: Draws atmospheric samples at precise, constant mass flow rates (50 to 1,000 mL/min) through detector or sorbent tubes.

  • Volume-Based Automated Shutoff: Utilizes real-time mass flow feedback and digital timers to automatically stop sampling when target collection volumes or time durations are reached.

Specifications

Integrated flow rate50 – 1000mL/min
Real-time flow rate Parametres50mL/min : 0.0 – 37.0 kPa , 100mL/min : 0.0 – 36.0 kPa
300mL/min : 0.0 – 33.0 kPa , 500mL/min : 0.0 – 29.0 kPa
700mL/min : 0.0 – 24.0 kPa , 1000mL/min : 0.0 – 16.0 kPa
Operating Temperature / Humidity rangeTemperature : 0 – 40 ºC(32- 104 ºF)
Relative humidity : 10 – 90 %RH(no condensation)
Dimensions150(W) x 75(D) x 100(H) mm
Weight500g (including batteries)

Features

  • Rotatable Tube Mount Assembly: Features a rotating inlet fitting that allows the pump housing to be mounted or rested at any angle without kinking the sampling tube.

  • Weather-Resistant Enclosure: Built with an IP54-equivalent dust-proof and drip-proof housing for outdoor atmospheric sampling and industrial field audits.

Applications

  • Hazardous Air Pollutant (HAP) Sampling: Measuring trace levels of VOCs, acetaldehyde, formaldehydes, or ethylene oxide in workplace environments.

  • Indoor Air Quality (IAQ) & Residential Audits: Monitoring indoor formaldehyde ($91text{P/PL}$ series) and organic solvents in homes, schools, and office buildings.

  • Long-Term Personal & Perimeter Monitoring: Collecting multi-hour TWA chemical samples across plant boundaries or industrial work shifts.

Downloads

Datasheet : Gastec GSP-400FT Automatic Air Sampling Pump

Related Products

Gastec GSP-400FT Automatic Air Sampling Pump

Gastec GSP-400FT Automatic Air Sampling Pump Flow volume of 50-1000mL/min can be set. Tubes are now available for more than 500 different applications.

Product Note:

No product notes available.

Categories: , Tags: , ,

Loading...

Description

Gastec GSP-400FT Automatic Air Sampling Pump

Gastec GSP-400FT Automatic Air Sampling Pump Gastec GSP-400FT Automatic Air Sampling Pump Flow volume of 50-1000mL/min can be set.

GASTEC Detector Tubes indicate concentrations directly by way of a calibrated scale printed on the tubes. At GASTEC, we endeavour to achieve highest quality detector tubes for analysing airborne gases/vapours, as well as pollutants in soil and water through our advanced state-of-the-art research and development. Through our efforts we have acquired a solid reputation among our customers in virtually all sectors of industry, commerce and society. Tubes are now available for more than 500 different applications.

Function

  • Mass Flow Controlled Sample Collection: Draws atmospheric samples at precise, constant mass flow rates (50 to 1,000 mL/min) through detector or sorbent tubes.

  • Volume-Based Automated Shutoff: Utilizes real-time mass flow feedback and digital timers to automatically stop sampling when target collection volumes or time durations are reached.

Specifications

Integrated flow rate50 – 1000mL/min
Real-time flow rate Parametres50mL/min : 0.0 – 37.0 kPa , 100mL/min : 0.0 – 36.0 kPa
300mL/min : 0.0 – 33.0 kPa , 500mL/min : 0.0 – 29.0 kPa
700mL/min : 0.0 – 24.0 kPa , 1000mL/min : 0.0 – 16.0 kPa
Operating Temperature / Humidity rangeTemperature : 0 – 40 ºC(32- 104 ºF)
Relative humidity : 10 – 90 %RH(no condensation)
Dimensions150(W) x 75(D) x 100(H) mm
Weight500g (including batteries)

Features

  • Rotatable Tube Mount Assembly: Features a rotating inlet fitting that allows the pump housing to be mounted or rested at any angle without kinking the sampling tube.

  • Weather-Resistant Enclosure: Built with an IP54-equivalent dust-proof and drip-proof housing for outdoor atmospheric sampling and industrial field audits.

Applications

  • Hazardous Air Pollutant (HAP) Sampling: Measuring trace levels of VOCs, acetaldehyde, formaldehydes, or ethylene oxide in workplace environments.

  • Indoor Air Quality (IAQ) & Residential Audits: Monitoring indoor formaldehyde ($91text{P/PL}$ series) and organic solvents in homes, schools, and office buildings.

  • Long-Term Personal & Perimeter Monitoring: Collecting multi-hour TWA chemical samples across plant boundaries or industrial work shifts.

Downloads

Datasheet : Gastec GSP-400FT Automatic Air Sampling Pump