Nitto Kasei PLASEAL B-UF for Train Car is mostly plausible to the area requiring frame-resistance such as transportation vehicles (train cars, vessels, etc.) and electric/telecommunication equipment.
Nitto Kasei PLASEAL B-UF for Train Car
Sealing for voids and spaces requires waterproofing, protection from insects, corrosion, dust prevention, and seal performance.
- Vehicles related: train cars, etc.
- Vessels related: inner sealing for water-proof glands, lightning equipment, traffic light devices, telecommunication equipment, etc.
How to Use:
- Please clean the surface where the sealing products will be applied, and be free of drainages such as oil, water, and dust.
- The sealing products can be applied by hand work, and you can use a stick or suitable instrument to support your work.
- The remaining products should be stored with the surface covered by some wrap like a plastic bag.
Applications
Sealing for voids and spaces requiring waterproof, protection from insects, corrosion, dust prevention and seal performance.
- Vehicles related: train cars, etc.
- Vessels related: inner sealing for water-proof gland, lightning equipment, traffic light device, telecommunication equipment, etc.
Specifications
ITEM |
PLASEAL B-UF |
Method |
Appearance |
Gray |
Observation |
Hardness |
64 |
JIS A 5752
Load:100g▪5sec |
Specific Gravity |
2.00 |
Convert weight in water |
Heat Resistance |
NP |
Originally measured
(80°C×72hr) |
Cold Resistance |
NP |
Originally measured
(-20°C×72hr) |
Flame Resistance |
UL-94 V-0 level |
Fire test of the plastic material
(Base on UL-94) |
Size(mm) |
80×40×160 |
|
Weight |
1kg/pack |
|
Packing |
20packs/case |
|
*The above inspection data is measured originally, so it does not guarantee as a standardized data.
*NP = Not Particular
NFPA130 |
Measured Value |
Criteria |
Test Standard |
Radiant Panel Index (Is) |
12.73 |
< 25 |
ASTM E162 |
Smoke Density (Ds) |
Flaming Mode
17 |
Non-Flaming Mode
2 |
< 100 |
ASTM E662 |
Toxic Gas
Generation
(ppm) |
HCN |
< 2 |
< 2 |
< 150 |
BSS 7239 |
CO |
183 |
10 |
< 3500 |
NOx |
< 2 |
< 2 |
< 100 |
SO2 |
< 1 |
< 1 |
< 100 |
HF |
< 1.5 |
< 1.5 |
< 200 |
HCI |
< 1 |
< 1 |
< 200 |
EN 45545-2 |
Measured Value |
Criteria
(R22/HL3) |
Test Standard |
Oxygen Index (OI) |
32.4 |
> 32 |
ISO 4589-2 |
Smoke Density |
15.5 |
< 150 |
EN 45545-2
ISO 5659-2 |
Toxic
Testing |
CO2 |
433 |
Toxicity Index
CITNLP(=ΣCITNLPi)0.03 |
< 0.75 |
EN 45545-2:2013
Annex C Method 2 |
CO |
14.90 |
HF |
0.19 |
HCL |
0.04 |
HBr |
0.00 |
HCN |
0.09 |
NOx |
0.10 |
SO2 |
0.19 |