onoae

CS Instruments FA 510/515

CS Instruments FA 510/515  Compared with the previous models the sensors and evaluation electronics have been improved once again, especially the integrated temperature compensation. This means Increased accuracy at different ambient temperatures and an improved resolution of the sensor signal.

CS Instruments FA 510/515

CS Instruments FA 510/515  In addition to the previously common 4…20 mA analog output the new generation of dew point sensors have a digital RS 485 interface (Modbus-RTU). All values e. g. dew point, temperature, and absolute humidity … which are measured and calculated by the dew point sensor can be retrieved via the Modbus protocol.

Compared with the previous models the sensors and evaluation electronics have been improved once again, especially the integrated temperature compensation. This means Increased accuracy at different ambient temperatures and an improved resolution of the sensor signal. Like the previous models, the new dew point sensors have excellent long-term stability and show reliable measured values. The sensor element is insensitive to condensation and due to the serial sintered cap made of stainless steel, it is protected against direct contact with soiled particles.

Features

  • Measuring range -80…20°Ctd
  • Analogue output 4…20 mA
  • Precise, long-term stability
  • Condensation insensitive
  • Quick response time
  • Pressure-tight up to 350 bar (special version
  • NEW: Modbus-RTU interface
  • NEW: Higher resolution of the sensor signal due to improved evaluation electronics
  • Sensor diagnosis on site by means of hand-held instrument or CS Service Software

Applications

  • Dew point measurement in the compressed
    air after adsorption dryer, membrane dryer,
    refrigeration dryer
  • Residual moisture/dew point measurement in
    gases such as oxygen, nitrogen, argon…
  • Residual moisture/dew point measurement
    after granulate dryers in the plastics industry

Specifications

  • Measuring range: -80…20 °Ctd, -20…50 °Ctd
  • Accuracy: ± 1 °C at 50…-20 °Ctd
    ± 2 °C at -20…-50 °Ctd
    ± 3 °C at -50…-80 °Ctd
  • Pressure range: -1…50 bar
    Special version up to 350 bar
  • Power supply: 24 VDC (10…36 VDC)
  • Protection class: IP 65
  • EMC: In acc. with DIN EN 61326-1
  • Operating temperature:
    -20…70 °C
  • Connection: M12, 5-pin
  • PC connection: Modbus-RTU interface (RS
    485)
  • Analogue output: 4…20 mA = -80…20 °Ctd
    4…20 mA = -20…50 °Ctd
    FA 510: 4…20 mA (3-wire)
    FA 515: 4…20 mA (2-wire)
  • Burden for analogue
    output:
    < 500 Ω
  • Screw-in thread: G 1/2″
    Optional: UNF 5/8″, NPT 1/2″
  • Dimensions: Ø 30 mm, length approx.
    130 mm
  • Via service software:
  • Choose units
  • Scaling
    % RH, °Ctd, g/m³, mg/m³,
    ppm V/V
    4…20 mA change

Downloads

Datasheet : CS Instruments FA 510_515 – Dew Point Sensor