onoae

Jain Technology Xonic 100L Clamp On Ultrasonic Flowmeter

Jain Technology Xonic 100L Clamp-On Ultrasonic Flowmeter measures transit-time of flow and uses DSP (digital signal processing) technology to analyze ultrasonic signals.

Loading...

Description

Jain Technology Xonic 100L Clamp-On Ultrasonic Flowmeter measures transit-time of flow and uses DSP (digital signal processing) technology to analyze ultrasonic signals.

This DSP technology can remove any noise from pipes and electronics. Also, Xonic 100 uses Cross-Correlation and FFT (Fast Fourier Transform) technology to make very clean ultrasonic signals. The measuring pipe is from 12 ~ 6,000mm, and the velocity range is from 0.02 ~ 20m/sec. Xonic 100 can measure very slow flow, so very suitable for block flow (leak) monitoring systems. Also, it has two 4-20mA inputs, so the user can use these inputs to receive pressure and temperature data without PLC

Clamp-on technology makes installation very simple. Users just attach clamp-on transducers on pipes or insert them with hot tap valve transducers drilled into a pipe. No need to stop the water supply for installation and after service. Xonic100L can work with many kinds of pipe, such as Steel, Stainless (SUS), Ductile Iron, Copper, A/C, PVC, PE, PB, FRP, or others if know the sound velocity. The turn-down ratio of Xonic 100L is more than 500 :1. Xonic 100L is the best flowmeter to check minimum flow during midnight. The Flow at midnight is down to 1 m3/h for 100 mm pipe and Xonic 100L can keep the accuracy. Xonic 100L uses Cross-Correlation technology. The technology is able to remove most noises outside the pipe. Also, Xonic 100L can measure liquids containing heavy air and slurry. Xonic 100L has a large color graphic LCD. It allows the user to read the flow, total, analog input data (pressure, level, etc.), and the ultrasonic signal diagram. So the user can check how the flowmeter works in the field without an oscilloscope as a diagnostic function. Xonic 100L is a dual beam or dual path is the basic model. Users can use as single channel flowmeters with one pair of transducers, and dual-channel or dual-path flowmeters with two pairs of transducers

Jain Technology Xonic 100L Performance

  • Clamp-on Type
  • Velocity 0.02~20m/s
  • Measure Water Contains 30% Air and Slurry
  • No Cutting Pipe for Installation
  • Oscilloscope Function
  •  DSP Technology (Cross Correlation)
  •  12 Patents
  •  Positive & Negative Flow Measurement
  • Two Analog Inputs for Pressure Level
  • Self-Diagnostic Functions
  • Touch Key Programming
  • Large Color Graphic LCD Display
  • Key Lock Function
  • 1,000,000 Points Datalogging

Features

Clamp-On Technology makes installation very simple. The user just attach clamp-on transducers on pipes or insertion with hot tap valve transducers drill to pipe. Do not need to stop water supply for installation and after service. Xonic100L can work with many kinds of pipes, such as Steel, Stainless (SUS), Ductile Iron, Copper, A/C, PVC, PE, PB, FRP or others if know sound velocity.

The turn-down ratio of Xonic 100L is more than 1000: 1 and Xonic 100L is the best flow meter to check minimum flow during mid-nights. The Flow in mid-night is down to 1 m3/ hr for 100 mm pipe and Xonic 100L can keep the accuracy.

Xonic 100L use Cross-Correlation technology. The technology is able to remove most noises outside the pipe. Also, Xonic 100L can measure liquids contain heavy air and slurry.

Xonic 100L has a large color graphic LCD. It allows a user to read the flow, total, analog input data (pressure, level, etc) and the ultrasonic signal diagram. So the user can check how to flow meter works in the field without oscilloscope as diagnostic functions.

Xonic 100L is a dual-beam or dual path that is a basic model. Users can use as single-channel flow meter with one pair transducers and dual-channel or dual path flow meters with two pair transducers.

Applications

  • Municipal Water, Waste Water
  • Block Flow Monitoring
  • Strong Acid, Solvent
  • Milk, Beer, Demi-water
  • Oil, Chemicals
  • Cool and Hot Water
  • Liquids contain Heavy Slurry and Air
  • Pulp, Steel Industries
  • Nuclear Power Plant
  • Sea Water

Specifications

Installation Clamp-on Ultrasonic Flowmeter
Principles Transit-Time, AR(Anti-Round) Mode
Measuring Pipe Size 12-6000mm
Accuracy ±1.0% (single path), ±0.5% (dual path)
Velocity ±0.02~20m/s
Turn-Down Ratio 500:1
Repeatability 0.25%
Required Straight Run Upstream 10D, Downstream 5D (single path) Upstream 5D, Downstream 3D (dual path)
CPU 32-bit microprocessor
Data Input 4-20mADC
 

Data Output

Two 4-20mADC for flow Relay for Total

RS-232C / RS-485 Modbus

Datalogger SD 2GB
 

Display

Color Graphic LCD Display (flowrate: 4.5digit, Total: 12digit) Flowrate, Velocity, Total (POS, NEG, NET), Input Data (AI), Delta T, Ultrasonic Signal Shape, Frequency
Temperature Range Flow Computer -20 ~ +75℃

Transducer -40 ~ +120℃

Power 110 ~ 220VAC, free voltage
Enclosure IP65
Transducer IP68, submersible