onoae

Zenner Two-Pipe Diaphragm Gas Meter

Zenner Two-pipe Diaphragm Gas Meter are Solid build quality, high accuracy, and safety making the Atmos®diaphragm gas meter a high-grade measuring instrument.

Zenner Two-Pipe Diaphragm Gas Meter is suitable for various gas media. The integrated calibration system coordinates the movement of the valves in relation to the optimum gas flow. The excellent linearity of the error curve is guaranteed even at low flow rates. Due to the valves’ optimum rotating characteristics, the Qmin value remains stable and the gas meter is resistant to contamination.

Zenner Two-Pipe Performance Characteristics:

  • Approved in accordance with MID by NMi
  • Integrated system to adjust the error curve
  • 0.8dm³ cyclic volume, suitable for the demand of G1.6 and G2.5
  • Long-term accurate measurement
  • Galvanized steel powder-coated housing for maximum corrosion resistance
  • Fire resistant (HTB) up to 0.1 bar according to EN1359
  • Working temperature range: -25 °C to +55 °C
  • Anti-corrosion performance

Zenner Two-pipe Diaphragm Gas Meter is available in sizes:

  • G1.6MS : 0.016 m3/h to 2.5 m3/h
  • G2.5MS : 0.025 m3/h to 4 m3/h

Features

  • Approved in accordance with MID by NMi
  • Integrated system to adjust the error curve
  • 0.8 dm³ cyclic volume, suitable for the demand of G1.6 and G2.5
  • Long-term accurate measurement
  • Galvanized steel powder-coated housing for maximum corrosion resistance
  • Fire resistant (HTB) up to 0.1 bar according to EN1359
  • Working temperature range: -25 °C to +55 °C
  • Anti-corrosion performance
  • Starting flow ≤ 1 dm3/h
  • Retrofittable with pulser

Applications

  • Natural gas
  • Town gas
  • Biogas
  • Liquid gas
  • Methane gas

Specifications

Atmos® G1.6S | G2.5S | G4S

Type G1.6S G2.5S G4S
Nominal Type Qn m³/h 1.6 2.5 4
Maximum Flow Rate Qmax m³/h 2.5 4 6
Minimum Flow Rate Qmin m³/h 0.016 0.025 0.04
Maximum operating pressure bar 0.5 0.5 0.5
Maximum permissible errors 0.1 Qmax ≤ Q ≤ Qmax

Qmin ≤ Q < 0.1 Qmax

± 1.5%

± 3%

± 1.5%

± 3%

± 1.5%

± 3%

Max. pressure loss mbar ≤ 2 ≤ 2 ≤ 2
Display range max. m³/h 99999.9998 99999.9998 99999.9998
Display range min. m³/h 0.0002 0.0002 0.0002
Accuracy class class 1.5 1.5 1.5
Cyclic volume dm³ 1.2 1.2 1.2
Pulse value m3/pulse 0.01 0.01 0.01
Weight 110/130 mm

152.4 mm

kg 1.8

2.0

1.8

2.0

1.8

2.0

Downloads

Datasheet: Zenner Two-pipe Diaphragm Gas Meter

Shopping Cart