CS Instruments VD 500 For FAD Measurement

CS Instruments VD 500 For FAD Measurement the integrated precise differential pressure sensor measures the differential pressure/dynamic pressure at the sensor tip. The pressure depends on the respective gas velocity. The flow is therefore easy to determine by means of the pipe diameter. The additional measurement of temperature and absolute pressure and calculation of the relevant density means that measuring can be carried out for various gases, a wide variety of temperatures, and pressures.

Loading...

Description

CS Instruments VD 500 For FAD Measurement the integrated precise differential pressure sensor measures the differential pressure/ dynamic pressure at the sensor tip. The pressure depends on the respective gas velocity. The flow is therefore easy to determine by means of the pipe diameter. The additional measurement of temperature and absolute pressure and calculation of the relevant density means that measuring can be carried out for various gases, a wide variety of temperatures, and pressures.

CS Instruments VD 500 For FAD Measurement

Benefits at a glance:
• Particularly suitable for extremely high flow rates
• Extremely fast response time: 100 ms
• Flow, total consumption, temperature, and pressure
• Measurement at high temperatures, max. temperature 180 °C
• Measurement in various gases by selecting the gas type, on request
• Can be used in pipes from DN 20 to DN 500
• Installation via 1/2″ ball valve under pressure
• RS 485 interface (Modbus-RTU), 4…20 mA, pulse output as standard

Features

  • Particularly suitable for extremely high flow rates
  • Extremely fast response time: 100 ms
  • Flow, total consumption, temperature and pressure
  • Measurement at high temperatures, max. temperature 200 °C
  • Measurement in various gases by selecting gas type, on request
  • Can be used in pipes from DN 20 to DN 500
  • Installation via 1/2″ ball valve under pressure
  • RS 485 interface (Modbus-RTU), 4…20 mA, pulse output as standard

Applications

  • FAD measurement of compressors
  • Compressed air audits
  • Efficiency measurement of compressed air systems
  • Measurement downstream of the compressor
  • Measurement at high temperatures
  • Measurement of fast processes

Specifications

  • Measuring range: up to 224 m/s / 600 m/s
  • Measured medium: Air, non-aggressive gases
  • Accuracy:
    (m.v.: of meas. value) (f.s.: of
    full scale)
    ± 1.5% of m.v. ± 0.3% of f.s.(20…224 m/s)
    ± 1.5% of m.v. (> 224 m/s)
  • Measuring principle: Diff erential pressure
  • Measuring span: 1:10
  • Response time: t 99: < 1 sec.
  • Temperature of the medium: -30 °…+180 °C
  • Operating pressure: Max. 20 bar
  • Ambient temperature: -30 °…+70 °C
  • Screw-in thread: G 1/2″, ISO 228
  • Power supply: 18…36 VDC, 5 W
  • Signal outputs: As standard:
    RS 485 (Modbus-RTU), 4…20 mA, pulse
    Optional:
    Ethernet Interface (PoE), M-Bus

Downloads

Datasheet: CS Instruments VD 500 – Flow Meter For FAD Measurement