FLOWMASONIC WUF100 J series is a portable transit-time ultra-sonic flowmeter With clamp-on transducers for non-invasive liquid measurement. Based on microprocessor , field programmable flow measurement technique allows no interruption to the process flow and has low installation costs.
Flowmasonic WUF 100 J Portable Ultrasonic Flowmeter
FLOWMASONIC WUF100 J series is a portable transit-time ultra-sonic flowmeter With clamp-on transducers for non-invasive liquid measurement.
Features
- Wide range,Velocities{0.01-+/-12m/s)
- Ni-MH Battery support at least 10 hours continuous operation
- Maximum temperature 160C
- Transducers for pipes size from 15 to 1000 mm{½”-40″)
- Transducers contains magnet devise, which can installed on metal pipe without mounting belt
- Data logger which records flowrate, date.total flow.signal condition (Etc Response time less than 1 second).
Applications
- Water Utility
- Water Conservancy & Resource
- College & University
- Manufacturing
- Draining Company
- Heating Supply Industry
- Petrochemical Industry
Specifications
Measuring principle | Transit time difference | |
Pipe Size | S Type : 15mm~65mm(1/2″~2.5″) M | |
Type : 80mm~250mm(3″~10″) | ||
L Type : 300mm~1000mm(12″~40″) | ||
Pipe Material | Cast Iron,Stainless steel,Ductile Iron, Copper, PVC,Aluminum,Asbestos, Fibergiass.Etc | |
Liner Material | Tar Epoxy, Rubber,Mortar, Polypropylene, Polystyrol, Polystyrene, polyester, Ebonite Poiyethylene, Tefion.Etc | |
Display | 4 Line LCD with illumination | |
Flowrate | 5 digit with decimal point | |
Totalizer | 8 digit, Forward, Reverse & Net values | |
Engineer unit | M3,Liter,US Gallon,Imperial Gallon, Million Gallon,Cubic Feet US Barrels Imperial Barrels,Oil Barrel | |
Time Unit | Second,Minute,Hour,Day | |
Other | Velocity,Date,Time,Signal condition | |
Accuracy | +-1%~+/-2% value of reading | |
2 +40.5% Value of reading(online calibration) | ||
Repeatability | +/-0.2% value of reading | |
Keypad | 18 Key with tactile action | |
Response time | Less than 1 second | |
Flou Velocity | 0.01~#/-12m/s | |
Resolution | 0.0001m/s | |
Ambient Temperature | -40 to +60 °C | |
Ambient Humidity | 90% RH or Less | |
Builtin Battery | Ni-MH Battery | |
Operation Time | >10 Hours | |
Charger | 90~260Vac 50/60 Hz,8-12 Hr charging | |
Data Storage | Operation parameters and totalization | |
Data are stored by EEPROM for more than 10 years | ||
Data Logger | 64 data include flowrate,totalizen,time,date | |
Output | Pulse (Open collector) | |
Alamr | High/Low with buzzer | |
Power consumption | Less than 2W | |
Dimension | 210 * 90 * 30mm | |
Weight | 8 Kg(17.6 Lbs) | |
Enclosure | IP65 |