Skip to main content

onoae

Best Gastec 600 Injection Type Gas Measurement System Propane

Gastec 600 Injection Type Gas Measurement System Propane

Product Note:

No product notes available.

Categories: , Tags: , ,

Description

Gastec 600 Injection Type Gas Measurement System Propane

Gastec No. 600 Injection-Type Gas Measurement System is a specialized, syringe-driven gas sampling kit engineered specifically for measuring high concentrations of Propane (C3H3).

Unlike standard Gastec colorimetric tubes that rely on a hand piston pump (like the GV-100) to pull ambient air across the reagent bed, the No. 600 system uses a 20 mL sampling syringe to directly inject a measured gas volume into specialized injection-type detector tubes (e.g., Gastec Tube No. 100B). This syringe injection method accommodates slow chemical reaction rates and high-concentration gas streams without saturating standard pump mechanisms.

 

Specifications

Substance to be measuredTube no. & nameMeasuring range
(ppm)
Scale range
(ppm)
No. of
tests
per box
Detector tube typeNotes
Propane100BPropane0.1-2.0%0.1-2.0%10Injection typeNo.600 (Propane)

Features

  • Compact, lightweight, and versatile(can be used anywhere)
  • Easy direct measuring and reading
  • No sampling pump necessary

Applications

  1. Break off both ends of a detector tube (No.100B for No.601 syringe or No.2HT for No.611 syringe) by using the tube tip cutter.
  2. Attach the syringe inlet to the syringe (No.601 or No.611) and collect 20ml of sample into the syringe by pulling its piston.
  3. Insert the tube securely into the syringe inlet with the arrow pointing away from the syringe. Inject the sample collected in the syringe into the detector tube in 2 minutes (for No.100B) or 20 seconds (for No.2HT), and read the indication.
  4. Please see the product manual for details.

Downloads

Datasheet : Gastec 600 Injection Type Gas Measurement System Propane

Related Products

Best Gastec 600 Injection Type Gas Measurement System Propane

Gastec 600 Injection Type Gas Measurement System Propane In No.600 System, samples are injected into detector tubes by using a syringe in order to measure gases in very high concentrations or slow in chemical reactions.

Product Note:

No product notes available.

Categories: , Tags: , ,

Loading...

Description

Gastec 600 Injection Type Gas Measurement System Propane

Gastec No. 600 Injection-Type Gas Measurement System is a specialized, syringe-driven gas sampling kit engineered specifically for measuring high concentrations of Propane (C3H3).

Unlike standard Gastec colorimetric tubes that rely on a hand piston pump (like the GV-100) to pull ambient air across the reagent bed, the No. 600 system uses a 20 mL sampling syringe to directly inject a measured gas volume into specialized injection-type detector tubes (e.g., Gastec Tube No. 100B). This syringe injection method accommodates slow chemical reaction rates and high-concentration gas streams without saturating standard pump mechanisms.

 

Specifications

Substance to be measuredTube no. & nameMeasuring range
(ppm)
Scale range
(ppm)
No. of
tests
per box
Detector tube typeNotes
Propane100BPropane0.1-2.0%0.1-2.0%10Injection typeNo.600 (Propane)

Features

  • Compact, lightweight, and versatile(can be used anywhere)
  • Easy direct measuring and reading
  • No sampling pump necessary

Applications

  1. Break off both ends of a detector tube (No.100B for No.601 syringe or No.2HT for No.611 syringe) by using the tube tip cutter.
  2. Attach the syringe inlet to the syringe (No.601 or No.611) and collect 20ml of sample into the syringe by pulling its piston.
  3. Insert the tube securely into the syringe inlet with the arrow pointing away from the syringe. Inject the sample collected in the syringe into the detector tube in 2 minutes (for No.100B) or 20 seconds (for No.2HT), and read the indication.
  4. Please see the product manual for details.

Downloads

Datasheet : Gastec 600 Injection Type Gas Measurement System Propane