Nominal Flow (Qₙₒₘ)*
|
800 kg/min (1763.7 lb/min)
|
Maximum Flow (Qₘₐₓ)*
|
900 kg/min (1984.2 lb/min)
|
Typical Minimum Flow (Qₘᵢₙ)*
|
10 kg/min (22.1 lb/min)
|
Serial Tube / Single Path
|
Flow rates Qmax, Qnom and Qmin for “serial” sensors will be 50% of the above listed parallel/dual path version.
|
Operating Temperature
|
Fluid temperature range options cover applications from -196°C to +350°C (-320°F to +662°F). For integral transmitter versions please refer to transmitter datasheet
|
Ambient Temperature
|
-50 °C to +80 °C (-60 °F to +180 °F) (standard)
|
Pressure Ratings
|
Up to 462 bar / 6701 psi – dependent upon material
|
Electrical Connection Sensor
w/o Integral Transmitter
|
M20 x 1.5 standard cable entry for JM, SM terminal box versions
Optional entries available : ½” NPT or M25 x 1.5 (only for SM) or ¾” NPT (only for SM)
Max. cable length to remote RHE transmitter 100 m / 328 ft
|
Sensor Enclosure Materials
|
Stainless steel 304 (standard), SS 316 (optional)
Coated aluminum terminal box, SS 316 terminal box (optional)
|
Enclosure Type
|
Protection class IP66, NEMA 4X (standard), IP66/67, NEMA 4X/6 (optional)
|
Wetted Materials
|
1.4571 (SS 316Ti), 1.4410 (SuperDuplex), 2.4602 (Alloy C22) – standard
Tantalum – Consult Factory
Seal material (manifold construction): PTFE
Additional/customer specific materials available upon request
|
Process Connections
|
Nearly any – the Rheonik AnyPipeFit Commitment. Consult factory for types/sizes not listed in this data sheet on the Mechanical Construction pages
|
Pressure Rating Compliance
|
Europe – PED: Module A2, Module B3.1+C2
Canada – CRN: Canadian Registration Number
|
Certifications and Approvals
|
ATEX / IECEx Approvals for Zone 0, 1, 2 (details see page 13)
North American Approvals Class I, Div. 1, 2, Gr. A,B,C,D, Zone 0, 1, 2
MID custody transfer approval (OIML R117)
American Bureau of Shipping (ABS) Product Type Approval for use on marine vessels
|
Testing and Inspection
|
All sensors are hydro tested, calibrated and supplied with a traceable calibration certificate. Customized calibration and testing services are available
|
Project Documentation and QA, Services
|
Rheonik offers a full set of services for large and complex engineering projects.
Typical services offered are, but not limited to:
•Certificates of origin and conformity, mill certificates
•Data books including WPAR, WQS, NDT, test & quality plans, functional testing, calibration procedures, customized packing, factory acceptance etc.
•Painting to project specification
•Start up and commissioning services on/offshore
|
Options
|
Enclosure heating for high temperature applications
Cleaning for oxygen service , …
For more consult factory
|