Description of EGE AGVU Ultrasonic Distances Sensor

are transmitting and receiving ultrasonic signals. These signals have a frequency range from 65 kHz up to 300 kHz. Ultrasonic sensors can be used for several different applications, for example:
diameter detection

  • loop tension
  • height detection
  • level measuring
  • counting

Cycle period

A short ultrasonic pulse is transmitted at the time 0, reflected by an object. The sensor receives this signal and converts it to an electric signal. The next pulse can be transmitted when the echo is faded away. This time period is called the cycle period. (Fig. 1)

Sensors with

  • long sensing ranges have long cycle periods and slow reaction time.
  • short sensing ranges have short cycle periods and fast reaction times.
EGE Ultrasonic Sensor Fig.1
EGE Ultrasonic Sensor Fig.1

Angle of beam
The energy of the ultrasonic pulse is transmitted in form of a cone along the transducer axis. The highest intensity is on the axis and decreases with rising angles. The angle of beam is defined by the angle through which the energy of the ultrasonic pulse is reduced of 33% of its maximum value.

The best detection is given by an object that stands vertically to the transducer axis. To give a save detection, the object should not have a greater angle than half of the angle of the beam (α/2). (Fig. 2) If the object is canted at a greater angle, there is no reflection of the ultrasonic pulses. An object with a flat surface and canted at an angle of 45° to the transducer axis refracts the ultrasonic pulse at an angle of 90°. An ultrasonic pulse can be compared to a light beam.

EGE Ultrasonic Sensor Fig.2
EGE Ultrasonic Sensor Fig.2

Voltage amplitude
During the transmission, the voltage amplitude of the ultrasonic pulse is approximate 80 V PP. The pulse period of the ultrasonic pulse depends on the duration of the transmission pulse and on the ringing time of the transducer. The voltage amplitude of the received echo is in the range of μV. (Fig. 3)

EGE Ultrasonic Sensor Fig.3
EGE Ultrasonic Sensor Fig.3

Blind zone
It is not possible to receive an echo during the transmission of the ultrasonic pulse. This time period defines the range of the blind zone. In this blind zone, it is not possible to measure a distance. (Fig. 4)

EGE Ultrasonic Sensor Fig.4
EGE Ultrasonic Sensor Fig.4

Features

The Feature of the AGVU Ultrasonic Sensor:

  • Metal face sensor
  • Switching point
  • M30
  • One-piece stainless steel housing
  • DC 18…30 V
  • PNP output
    Teach-in programming

Applications

Non-contact detection of:

  • distances
  • presence
  • level
  • diameter
  • position

Independent of:

  • material
  • color
  • light
  • smoke
  • dust

Specifications

Design M30x1.5
Sensing range 150…1500 mm
Output EGE Output 4
ID-No. P72033
Type AGVU 1500 GSP
Supply voltage 18…30 VDC
Current consumption < 40 mA
Switching current 500 mA
Repeatability ±0.2 %
Switching frequency 7 Hz
Ambient temperature – 15…+70 °C
Protection IP 68 + IP 69 [EN   60529]
Hosuing material AISI 316 Ti
Connection M12 connector
Accessories Connecting cable type SLG 5-2 (Z01150)