Fluidwell D014 DIN Panel Mount Flow Rate Indicator Watertight DIN panel mount indicators, the better alternative for your existing, not waterproof panel meters.

Description of Fluidwell D014 DIN Panel Mount Flow Rate Indicator

is a local, panel mount indicator / transmitter to display the actual flow rate, total and accumulated total. The total can be reset to zero by pressing the CLEAR button twice. The eleven digit accumulated total however can not be reset to zero. Related to the acculmulated total, a scaled pulse is generated for re-transmitting the count on the display.

Fluidwell D014 DIN Panel Mount Flow Rate Indicator Advantages
  • Unique, robust IP66, IP67 (NEMA Type4X) panel mount front enclosure made of die cast aluminum, allowing even big jets of water and total immersion.
  • Familiar easy operation with the Fluidwell “Know one, know them all” configuration structure, saving time, cost and aggravation.

Features

  • Displays flow rate, total and accumulated total.
  • Large 17mm (0.67″) digits for flow rate or total.
  • Selectable on-screen engineering units; volumetric or mass.
  • Ability to process all types of flowmeter signals.
  • Auto backup of settings and running totals.
  • Ambient temperature: -40°C to +80°C (-40°F to 176°F).
  • LED backlight option.
  • Easy configuration with clear alphanumerical display.
  • Aluminum DIN front panel of 144 x 72mm (5.67” x 2.83”) according DIN 43700 / IEC 61554.
  • Various accessories are available for this product.

Applications

  • The D014 fits in flow measurement applications where re-transmission of the totalizer function is required.
  • The D-Series is a DIN-sized display and the better alternative for your existing, not waterproof, front panel mount indicators in extreme weather outdoor applications or e.g. in food industries where working environments are often cleaned with powerful water jets.

Specifications

Signal Inputs

Flowmeter Inputs

  • Pulse type inputs:
    Reed-switch, NAMUR, NPN/PNP pulse, Sine wave (coil), active pulse signal.
  • (0)4 – 20mA.
  • 0 – 10V DC.

Signal Outputs

Pulse outputs

  • Function:Scaled pulse output according to accumulated total (e.g. one pulse every 3.25 gallons).
    frequency: 500Hz.
    Adjustable pulse length from 1 msec. to 10 seconds.
  • Type:One passive signal output, an active signal output or a robust, highly isolated (NO/NC) relay.

Alarm outputs

  • None

Analog outputs

  • None

Supply

Power Supply

  • Basic: 8 – 30V DC (no real sensor supply).
  • Long life Lithium battery.
  • 4 – 20mA input Loop-powered.
  • 24V AC/DC + sensor supply.
  • 115 – 230V AC + sensor supply.

Sensor Supply

  • 2 / 3V DC.
  • 2, 12 & 24V DC.

Hazardous Area

Intrinsically Safe

  • For Intrinsically Safe applications we recommend the F-Series.

Explosion Proof

  • For Explosion Proof applications we recommend the E-Series.

Communication

  • Modbus communication available on F1-Series
  • HART communication is available with the F018 & E018Flow rate Monitor / Totalizers.

 

Downloads

Datasheet: Fluidwell D014 DIN Panel Mount Flow Rate Indicator

Related Products

DIN Panel Mount Flow Rate IndicatorFluidwell D014

Watertight DIN panel mount indicators, the better alternative for your existing, not waterproof panel meters.

The D014 is a local, panel mount indicator / transmitter to display the actual flow rate, total and accumulated total. The total can be reset to zero by pressing the CLEAR button twice. The eleven digit accumulated total however can not be reset to zero. Related to the acculmulated total, a scaled pulse is generated for re-transmitting the count on the display.

Product Note:

No product notes available.

Loading...

Description

Fluidwell D014 DIN Panel Mount Flow Rate Indicator Watertight DIN panel mount indicators, the better alternative for your existing, not waterproof panel meters.

Description of Fluidwell D014 DIN Panel Mount Flow Rate Indicator

is a local, panel mount indicator / transmitter to display the actual flow rate, total and accumulated total. The total can be reset to zero by pressing the CLEAR button twice. The eleven digit accumulated total however can not be reset to zero. Related to the acculmulated total, a scaled pulse is generated for re-transmitting the count on the display.

Fluidwell D014 DIN Panel Mount Flow Rate Indicator Advantages
  • Unique, robust IP66, IP67 (NEMA Type4X) panel mount front enclosure made of die cast aluminum, allowing even big jets of water and total immersion.
  • Familiar easy operation with the Fluidwell “Know one, know them all” configuration structure, saving time, cost and aggravation.

Features

  • Displays flow rate, total and accumulated total.
  • Large 17mm (0.67″) digits for flow rate or total.
  • Selectable on-screen engineering units; volumetric or mass.
  • Ability to process all types of flowmeter signals.
  • Auto backup of settings and running totals.
  • Ambient temperature: -40°C to +80°C (-40°F to 176°F).
  • LED backlight option.
  • Easy configuration with clear alphanumerical display.
  • Aluminum DIN front panel of 144 x 72mm (5.67” x 2.83”) according DIN 43700 / IEC 61554.
  • Various accessories are available for this product.

Applications

  • The D014 fits in flow measurement applications where re-transmission of the totalizer function is required.
  • The D-Series is a DIN-sized display and the better alternative for your existing, not waterproof, front panel mount indicators in extreme weather outdoor applications or e.g. in food industries where working environments are often cleaned with powerful water jets.

Specifications

Signal Inputs

Flowmeter Inputs

  • Pulse type inputs:
    Reed-switch, NAMUR, NPN/PNP pulse, Sine wave (coil), active pulse signal.
  • (0)4 – 20mA.
  • 0 – 10V DC.

Signal Outputs

Pulse outputs

  • Function:Scaled pulse output according to accumulated total (e.g. one pulse every 3.25 gallons).
    frequency: 500Hz.
    Adjustable pulse length from 1 msec. to 10 seconds.
  • Type:One passive signal output, an active signal output or a robust, highly isolated (NO/NC) relay.

Alarm outputs

  • None

Analog outputs

  • None

Supply

Power Supply

  • Basic: 8 – 30V DC (no real sensor supply).
  • Long life Lithium battery.
  • 4 – 20mA input Loop-powered.
  • 24V AC/DC + sensor supply.
  • 115 – 230V AC + sensor supply.

Sensor Supply

  • 2 / 3V DC.
  • 2, 12 & 24V DC.

Hazardous Area

Intrinsically Safe

  • For Intrinsically Safe applications we recommend the F-Series.

Explosion Proof

  • For Explosion Proof applications we recommend the E-Series.

Communication

  • Modbus communication available on F1-Series
  • HART communication is available with the F018 & E018Flow rate Monitor / Totalizers.

 

Downloads