Skip to main content

onoae

Best Gastec P-138-H Permeation Tube Methylene Chloride

Gastec P-138-H Permeation Tube Methylene Chloride

Product Note:

No product notes available.

Categories: , Tags: , ,

Description

Gastec P-138-H Permeation Tube Methylene Chloride

Gastec P-138-H Permeation Tube Methylene Chloride Generating calibration gas with a permeation tube with Concentration range 0.3 – 15.8 ppm. When housed inside a constant-temperature dynamic gas calibration generator (such as the Gastec PD-1B or standard laboratory calibration diluters), it releases a certified micro-rate mass flow of pure methylene chloride through a fluoropolymer membrane into a controlled dilution air or nitrogen stream.

WARNING:

  1. Use only Gastec detector tube in a Gastec Pump.
  2. Do not interchange or use non-Gastec parts of components in Gastec’s detector tube and pump system.
  3. The use of non-Gastec parts of component in Gastec’s detector tube and pump system, or use of a non-Gastec detector tube with a Gastec pump, or use of a Gastec detector tube with a non-Gastec pump may result in property damage, serious bodily injury, and death, voids all warranties, and voids all performance and data accuracy guarantees.

Application of the tube:

Use this tube for detecting Hydrogen fluoride in the air or in industrial areas and for determining the environmental atmospheric condition.

Specifications

ParameterSpecification
ManufacturerGastec Corporation
Part Number / ModelP-138-H / P138H
Target Chemical VaporMethylene Chloride / Dichloromethane ($text{CH}_2text{Cl}_2$)
Permeation MembraneFluoropolymer (FEP/Teflon) capillary reservoir
Certified Operating Temp$30.0^circtext{C to }40.0^circtext{C}$ (specified on individual calibration certificate)
Primary Output RangeGenerates $0.5text{ to }50.0text{ ppm}$ (dependent on carrier gas flow rate)
Expected Service Life6 to 12 months (determined by operating temperature and initial fill mass)
Compatible EquipmentGastec PD-1B / PD-1C Gas Generator series, standard dynamic gas diluters

Features

Concentration range 0.3 – 15.8 ppm

Applications

  • Chemical & Pharmaceutical Plant Safety: Calibrating photoionization (PID), flame ionization (FID), and gas chromatograph (GC) instruments used for workplace air monitoring in paint stripping, pharmaceutical extraction, and chemical synthesis facilities.

  • Colorimetric Detector Tube Validation: Laboratory verification and accuracy auditing of Gastec Methylene Chloride detector tubes (such as Gastec 138 series).

  • Industrial Hygiene Audits: Generating low-ppm span standards to verify leak detection equipment and ambient monitoring alarms for volatile halogenated hydrocarbon vapors.

Downloads

Related Products

Best Gastec P-138-H Permeation Tube Methylene Chloride

Gastec P-138-H Permeation Tube Methylene Chloride Generating calibration gas with a permeation tube with Concentration range 0.3 – 15.8 ppm.

Product Note:

No product notes available.

Categories: , Tags: , ,

Loading...

Description

Gastec P-138-H Permeation Tube Methylene Chloride

Gastec P-138-H Permeation Tube Methylene Chloride Generating calibration gas with a permeation tube with Concentration range 0.3 – 15.8 ppm. When housed inside a constant-temperature dynamic gas calibration generator (such as the Gastec PD-1B or standard laboratory calibration diluters), it releases a certified micro-rate mass flow of pure methylene chloride through a fluoropolymer membrane into a controlled dilution air or nitrogen stream.

WARNING:

  1. Use only Gastec detector tube in a Gastec Pump.
  2. Do not interchange or use non-Gastec parts of components in Gastec’s detector tube and pump system.
  3. The use of non-Gastec parts of component in Gastec’s detector tube and pump system, or use of a non-Gastec detector tube with a Gastec pump, or use of a Gastec detector tube with a non-Gastec pump may result in property damage, serious bodily injury, and death, voids all warranties, and voids all performance and data accuracy guarantees.

Application of the tube:

Use this tube for detecting Hydrogen fluoride in the air or in industrial areas and for determining the environmental atmospheric condition.

Specifications

ParameterSpecification
ManufacturerGastec Corporation
Part Number / ModelP-138-H / P138H
Target Chemical VaporMethylene Chloride / Dichloromethane ($text{CH}_2text{Cl}_2$)
Permeation MembraneFluoropolymer (FEP/Teflon) capillary reservoir
Certified Operating Temp$30.0^circtext{C to }40.0^circtext{C}$ (specified on individual calibration certificate)
Primary Output RangeGenerates $0.5text{ to }50.0text{ ppm}$ (dependent on carrier gas flow rate)
Expected Service Life6 to 12 months (determined by operating temperature and initial fill mass)
Compatible EquipmentGastec PD-1B / PD-1C Gas Generator series, standard dynamic gas diluters

Features

Concentration range 0.3 – 15.8 ppm

Applications

  • Chemical & Pharmaceutical Plant Safety: Calibrating photoionization (PID), flame ionization (FID), and gas chromatograph (GC) instruments used for workplace air monitoring in paint stripping, pharmaceutical extraction, and chemical synthesis facilities.

  • Colorimetric Detector Tube Validation: Laboratory verification and accuracy auditing of Gastec Methylene Chloride detector tubes (such as Gastec 138 series).

  • Industrial Hygiene Audits: Generating low-ppm span standards to verify leak detection equipment and ambient monitoring alarms for volatile halogenated hydrocarbon vapors.

Downloads