Gastec P-163-H Permeation Tube Ethylene Oxide

Gastec P-163-H Permeation Tube Ethylene Oxide Generating calibration gas with a permeation tube. with Concentration range 0.5 – 23 ppm. When housed inside a constant-temperature dynamic gas calibration generator (such as the Gastec PD-1B or standard laboratory calibration diluters), it releases a certified micro-rate mass flow of pure ethylene oxide through a fluoropolymer membrane into a controlled dilution air or nitrogen stream.

WARNING:

  1. Use only Gastec detector tube in a Gastec Pump.
  2. Do not interchange or use non-Gastec parts of components in Gastec’s detector tube and pump system.
  3. The use of non-Gastec parts of component in Gastec’s detector tube and pump system, or use of a non-Gastec detector tube with a Gastec pump, or use of a Gastec detector tube with a non-Gastec pump may result in property damage, serious bodily injury, and death, voids all warranties, and voids all performance and data accuracy guarantees.

Application of the tube:

Use this tube for detecting Hydrogen fluoride in the air or in industrial areas and for determining the environmental atmospheric condition.

Specifications

Key Technical Specifications

ParameterSpecification
ManufacturerGastec Corporation
Part Number / ModelP-163-H / P163H
Target Chemical VaporEthylene Oxide / Oxirane ($text{C}_2text{H}_4text{O}$)
Permeation MembraneFluoropolymer (FEP/Teflon) capillary reservoir
Certified Operating Temp$30.0^circtext{C to }40.0^circtext{C}$ (specified on individual calibration certificate)
Primary Output RangeGenerates $0.2text{ to }50.0text{ ppm}$ (dependent on carrier gas flow rate)
Expected Service Life6 to 12 months (determined by operating temperature and initial fill mass)
Compatible EquipmentGastec PD-1B / PD-1C Gas Generator series, standard dynamic gas diluters

Features

Concentration range 0.5 – 23 ppm

Applications

  • Medical Sterilization & Healthcare Audits: Calibrating photoionization (PID), gas chromatograph (GC), and electrochemical sensors used for workplace air monitoring in medical device sterilization facilities and hospital central sterile supply departments.

  • Colorimetric Detector Tube Validation: Laboratory verification and accuracy auditing of Gastec Ethylene Oxide detector tubes (such as Gastec 163 series).

  • Industrial Hygiene Audits: Generating low-ppm span standards to verify leak detection equipment and ambient monitoring alarms for toxic, flammable epoxide vapors.

Downloads

Related Products

Gastec P-163-H Permeation Tube Ethylene Oxide

Gastec P-163-H Permeation Tube Ethylene Oxide Generating calibration gas with a permeation tube. with Concentration range 0.5 – 23 ppm.

Product Note:

No product notes available.

Categories: , Tags: , ,

Loading...

Description

Gastec P-163-H Permeation Tube Ethylene Oxide

Gastec P-163-H Permeation Tube Ethylene Oxide Generating calibration gas with a permeation tube. with Concentration range 0.5 – 23 ppm. When housed inside a constant-temperature dynamic gas calibration generator (such as the Gastec PD-1B or standard laboratory calibration diluters), it releases a certified micro-rate mass flow of pure ethylene oxide through a fluoropolymer membrane into a controlled dilution air or nitrogen stream.

WARNING:

  1. Use only Gastec detector tube in a Gastec Pump.
  2. Do not interchange or use non-Gastec parts of components in Gastec’s detector tube and pump system.
  3. The use of non-Gastec parts of component in Gastec’s detector tube and pump system, or use of a non-Gastec detector tube with a Gastec pump, or use of a Gastec detector tube with a non-Gastec pump may result in property damage, serious bodily injury, and death, voids all warranties, and voids all performance and data accuracy guarantees.

Application of the tube:

Use this tube for detecting Hydrogen fluoride in the air or in industrial areas and for determining the environmental atmospheric condition.

Specifications

Key Technical Specifications

ParameterSpecification
ManufacturerGastec Corporation
Part Number / ModelP-163-H / P163H
Target Chemical VaporEthylene Oxide / Oxirane ($text{C}_2text{H}_4text{O}$)
Permeation MembraneFluoropolymer (FEP/Teflon) capillary reservoir
Certified Operating Temp$30.0^circtext{C to }40.0^circtext{C}$ (specified on individual calibration certificate)
Primary Output RangeGenerates $0.2text{ to }50.0text{ ppm}$ (dependent on carrier gas flow rate)
Expected Service Life6 to 12 months (determined by operating temperature and initial fill mass)
Compatible EquipmentGastec PD-1B / PD-1C Gas Generator series, standard dynamic gas diluters

Features

Concentration range 0.5 – 23 ppm

Applications

  • Medical Sterilization & Healthcare Audits: Calibrating photoionization (PID), gas chromatograph (GC), and electrochemical sensors used for workplace air monitoring in medical device sterilization facilities and hospital central sterile supply departments.

  • Colorimetric Detector Tube Validation: Laboratory verification and accuracy auditing of Gastec Ethylene Oxide detector tubes (such as Gastec 163 series).

  • Industrial Hygiene Audits: Generating low-ppm span standards to verify leak detection equipment and ambient monitoring alarms for toxic, flammable epoxide vapors.