onoae

Sale!

Original price was: Rp 146.000.000.Current price is: Rp 145.000.000.

ELBFIR0015, Board Assembly For Jockey Pump Controller (905102) with Jockey Pump Cover Kit

Minimum Order: 1 units

Lead Time: 10 weeks

Lead Time Note: 8-10 weeks

Product Note:

1set

Description

Firetrol® FTA750 Limited Service Controllers are intended for use with small electric motor driven fire pumps where the capacity of the power source permits full voltage starting. Full voltage is applied to the motor as soon as the controller is actuated. The controller monitors, displays and records fire pump system information.Limited Service Controllers may be used where they are acceptable to the authority having jurisdiction.

Features

  • Automatic Operation: Automatically starts the jockey pump when the system pressure drops below a set level.
  • Timers:
    • Minimum Run Timer: Allows the pump to run for a set period after starting.
    • On-Delay Timer: Delays the start of the pump.
    • Pump Restart Timer: Prevents short cycling of the motor.

Applications

  • Pressure Maintenance in Fire Sprinkler Systems: The main purpose is to maintain a constant, elevated water pressure within a fire sprinkler piping system. All sprinkler systems have minor leaks, which can cause the pressure to gradually drop.
  • Preventing Unnecessary Fire Pump Activation: Without a jockey pump, the main, high-powered fire pump would have to start every time there is a minor pressure drop. This would lead to frequent, unnecessary starts, causing excessive wear and tear on the main pump, wasting energy, and potentially triggering false alarms.

  • Energy Efficiency: By handling the small pressure drops, the jockey pump (which is much smaller and less powerful than the main fire pump) ensures that the main pump only activates when there is a significant drop in pressure, as would happen during a real fire. This saves a considerable amount of energy.

  • Industrial and Commercial Facilities: These controllers are used in a wide range of buildings that require a fire suppression system to comply with safety codes, including:

    • Commercial buildings (office buildings, shopping centers)

    • Industrial facilities (factories, warehouses)

    • Other large-scale commercial and residential environments.

Specifications

  • Operating Voltage: The controller is available in multiple voltage configurations, including both single-phase and three-phase options.
    • 3-Phase: 200-600V AC (with specific models for 200-208V, 220-240V, 380-415V, 440-480V, and 550-600V).
    • 1-Phase: 110-240V AC (with specific models for 110-120V, 200-208V, and 220-240V).
  • Starting Method: Varies by model, but often Wye-Delta Open Transition or Across-the-Line starting.
  • Short Circuit Current Ratings (SCCR): The controller has a short-circuit current rating that varies with the voltage. For a 3-phase, 480V system, for example, the SCCR can be as high as 65kA.
  • Horsepower Rating: The maximum horsepower rating of the jockey pump motor the controller can handle is dependent on the voltage. For example, some models can handle up to 50 HP at 480V.

Reviews

There are no reviews yet.

Only logged in customers who have purchased this product may leave a review.

Related Products

Sale!

ELBFIR0015, Board Assembly For Jockey Pump Controller (905102) with Jockey Pump Cover Kit

ELBFIR0015, Board Assembly For Jockey Pump Controller (905102) with Jockey Pump Cover Kit Limited Service Controllers may be used where they are acceptable to the authority having jurisdiction.

Minimum Order: 1 units

Lead Time: 10 weeks

Lead Time Note: 8-10 weeks

Product Note:

1set

Original price was: Rp 146.000.000.Current price is: Rp 145.000.000.

Loading...

Description

Firetrol® FTA750 Limited Service Controllers are intended for use with small electric motor driven fire pumps where the capacity of the power source permits full voltage starting. Full voltage is applied to the motor as soon as the controller is actuated. The controller monitors, displays and records fire pump system information.Limited Service Controllers may be used where they are acceptable to the authority having jurisdiction.

Features

  • Automatic Operation: Automatically starts the jockey pump when the system pressure drops below a set level.
  • Timers:
    • Minimum Run Timer: Allows the pump to run for a set period after starting.
    • On-Delay Timer: Delays the start of the pump.
    • Pump Restart Timer: Prevents short cycling of the motor.

Applications

  • Pressure Maintenance in Fire Sprinkler Systems: The main purpose is to maintain a constant, elevated water pressure within a fire sprinkler piping system. All sprinkler systems have minor leaks, which can cause the pressure to gradually drop.
  • Preventing Unnecessary Fire Pump Activation: Without a jockey pump, the main, high-powered fire pump would have to start every time there is a minor pressure drop. This would lead to frequent, unnecessary starts, causing excessive wear and tear on the main pump, wasting energy, and potentially triggering false alarms.

  • Energy Efficiency: By handling the small pressure drops, the jockey pump (which is much smaller and less powerful than the main fire pump) ensures that the main pump only activates when there is a significant drop in pressure, as would happen during a real fire. This saves a considerable amount of energy.

  • Industrial and Commercial Facilities: These controllers are used in a wide range of buildings that require a fire suppression system to comply with safety codes, including:

    • Commercial buildings (office buildings, shopping centers)

    • Industrial facilities (factories, warehouses)

    • Other large-scale commercial and residential environments.

Specifications

  • Operating Voltage: The controller is available in multiple voltage configurations, including both single-phase and three-phase options.
    • 3-Phase: 200-600V AC (with specific models for 200-208V, 220-240V, 380-415V, 440-480V, and 550-600V).
    • 1-Phase: 110-240V AC (with specific models for 110-120V, 200-208V, and 220-240V).
  • Starting Method: Varies by model, but often Wye-Delta Open Transition or Across-the-Line starting.
  • Short Circuit Current Ratings (SCCR): The controller has a short-circuit current rating that varies with the voltage. For a 3-phase, 480V system, for example, the SCCR can be as high as 65kA.
  • Horsepower Rating: The maximum horsepower rating of the jockey pump motor the controller can handle is dependent on the voltage. For example, some models can handle up to 50 HP at 480V.