onoae

Fluidwell E126-EG Explosion Proof Flowcomputer

Product Note:

No product notes available.

Description

Fluidwell E126-EG Explosion Proof Flowcomputer

Fluidwell E126-EG Explosion Proof Flowcomputer These unequalled explosion proof (Ex d) flow rate indicators / totalizers deliver user-friendliness in the toughest conditions.

The robust E126-EG is designed with a focus on your safety. It’s beyond fulfilling the rules for hazardous area approvals, because the environment is often much tougher than explosion proof requirements demand. Experiencing flaws in your processes due to rain, snow, salty atmospheres (offshore) or early wear? The E126 delivers accurate measurement while withstanding the harshest conditions. Fluidwell E126-EG Explosion Proof Flowcomputer

 

Features

  • Explosion proof according ATEX, IECEx, FM and CSA C-US.
  • Aluminum or high grade stainless steel Ex d enclosure.
  • Easy installation with the spacious chamber and plug & play connectors.
  • Cost saving with an easy to install, 1” NPT thread for direct flowmeter mounting.
  • Key information at a glance as the display shows flow rate, total, temperature, measuring units and a flow rate indicating speedometer.
  • Easy K-factor and engineering unit configuration for volumetric or mass. Learn more with this interactive tutorial.
  • 7 digit flow rate / total and 11 digit accumulated total.
  • Bright LED backlight.
  • Current day total (Daily total), previous day total (both non-resettable) and 15 historical day totals can be displayed.
  • Easy configurable via PC with free downloadable remote configuration tool and special communication cable (ACE01/02/06/07).
  • Auto backup of settings and running totals.
  • Ambient temperature: -40°C to +70°C (-40°F to 158°F).
  • Various accessories are available for this product.

Applications

  • Flow measurement in applications where nett gas flow calculation at base conditions is desired.
  • The E-Series can be used in rough and tough applications, beyond being just explosion proof. Its sturdy design and ease of use are unequaled by any other explosion proof indicator in the market! The E-Series is always your first and safest choice in explosion proof applications.

Specifications

Signal Inputs

Flowmeter Inputs

  • Pulse type inputs:
    Reed-switch, NAMUR, NPN/PNP pulse, Sine wave (coil), active pulse signal.

Temperature Inputs

  • PT100 – 2, 3 or 4 wire PRTD sensor.
  • (0)4 – 20mA. Contact us for latest specifications.

Pressure Inputs

  • (0)4 – 20mA. Contact us for latest specifications.

Signal Outputs

Pulse outputs

  • Function:Scaled pulse output according to corrected accumulated total and unscaled pulse input retransmission. Max. frequency: 500Hz. Retransmission: Minimum pulse duration: 50µs, Adjustable pulse length from 1 msec. Up to 10 seconds.
  • Type:One passive NPN transistor and one isolated electro-mechanical relay.

Alarm outputs

  • None

Analog outputs

  • Function:Re-transmitting the corrected flow rate – the output can be scaled to any range (e.g. 200 L/min to 1200 L/min).
  • Type:One galvanically isolated, loop powered 4 – 20mA output.

Supply

Power Supply

  • Long life Lithium battery.
  • 4 – 20mA. Output loop-powered.
  • 9 – 27V DC.

Sensor Supply

  • 3, 8.2, 12, 24V DC.

Hazardous Area

Intrinsically Safe

  • For Intrinsically Safe applications we recommend the F-Series.

Explosion Proof

  • ATEX:
    Gas: II 2 G Ex d IIC T6 Gb.
    Dust: II 2 D Ex tb IIIC T85°C Db.
  • IECEX:
    Gas: Ex d IIC T6 Gb.
    Dust: Ex tb IIIC T85°C Db.
  • FM and CSA C-US:
    XP (Explosion-proof): Class I, Division 1, Groups A, B, C, D.
    DIP (Dust-Ignition-proof): Class II/III, Div. 1, Groups E, F, & G.
    Gas: Class I, Zone 1, AEx d IIC T6 Gb.
    Dust: Zone 21, AEx tb IIIC T85°C Db.

Communication

  • Function:Reading display information and reading / writing all configuration settings.
  • Type:RS232, RS485 2-wire Modbus RTU or Local USB.
  • Remote configuration via free downloadable remote configuration tool (see dropdown download above).
  • HART communication is available with the F018 & E018Flow rate Monitor / Totalizers.

 

Downloads

Datasheet: Fluidwell E126-EG Explosion Proof Flowcomputer

Related Products

Fluidwell E126-EG Explosion Proof Flowcomputer

Fluidwell E126-EG Explosion Proof Flowcomputer These unequalled explosion proof (Ex d) flow rate indicators / totalizers deliver user-friendliness in the toughest conditions. Fluidwell E126-EG Explosion Proof Flowcomputer

Product Note:

No product notes available.

Loading...

Description

Fluidwell E126-EG Explosion Proof Flowcomputer

Fluidwell E126-EG Explosion Proof Flowcomputer These unequalled explosion proof (Ex d) flow rate indicators / totalizers deliver user-friendliness in the toughest conditions.

The robust E126-EG is designed with a focus on your safety. It’s beyond fulfilling the rules for hazardous area approvals, because the environment is often much tougher than explosion proof requirements demand. Experiencing flaws in your processes due to rain, snow, salty atmospheres (offshore) or early wear? The E126 delivers accurate measurement while withstanding the harshest conditions. Fluidwell E126-EG Explosion Proof Flowcomputer

 

Features

  • Explosion proof according ATEX, IECEx, FM and CSA C-US.
  • Aluminum or high grade stainless steel Ex d enclosure.
  • Easy installation with the spacious chamber and plug & play connectors.
  • Cost saving with an easy to install, 1” NPT thread for direct flowmeter mounting.
  • Key information at a glance as the display shows flow rate, total, temperature, measuring units and a flow rate indicating speedometer.
  • Easy K-factor and engineering unit configuration for volumetric or mass. Learn more with this interactive tutorial.
  • 7 digit flow rate / total and 11 digit accumulated total.
  • Bright LED backlight.
  • Current day total (Daily total), previous day total (both non-resettable) and 15 historical day totals can be displayed.
  • Easy configurable via PC with free downloadable remote configuration tool and special communication cable (ACE01/02/06/07).
  • Auto backup of settings and running totals.
  • Ambient temperature: -40°C to +70°C (-40°F to 158°F).
  • Various accessories are available for this product.

Applications

  • Flow measurement in applications where nett gas flow calculation at base conditions is desired.
  • The E-Series can be used in rough and tough applications, beyond being just explosion proof. Its sturdy design and ease of use are unequaled by any other explosion proof indicator in the market! The E-Series is always your first and safest choice in explosion proof applications.

Specifications

Signal Inputs

Flowmeter Inputs

  • Pulse type inputs:
    Reed-switch, NAMUR, NPN/PNP pulse, Sine wave (coil), active pulse signal.

Temperature Inputs

  • PT100 – 2, 3 or 4 wire PRTD sensor.
  • (0)4 – 20mA. Contact us for latest specifications.

Pressure Inputs

  • (0)4 – 20mA. Contact us for latest specifications.

Signal Outputs

Pulse outputs

  • Function:Scaled pulse output according to corrected accumulated total and unscaled pulse input retransmission. Max. frequency: 500Hz. Retransmission: Minimum pulse duration: 50µs, Adjustable pulse length from 1 msec. Up to 10 seconds.
  • Type:One passive NPN transistor and one isolated electro-mechanical relay.

Alarm outputs

  • None

Analog outputs

  • Function:Re-transmitting the corrected flow rate – the output can be scaled to any range (e.g. 200 L/min to 1200 L/min).
  • Type:One galvanically isolated, loop powered 4 – 20mA output.

Supply

Power Supply

  • Long life Lithium battery.
  • 4 – 20mA. Output loop-powered.
  • 9 – 27V DC.

Sensor Supply

  • 3, 8.2, 12, 24V DC.

Hazardous Area

Intrinsically Safe

  • For Intrinsically Safe applications we recommend the F-Series.

Explosion Proof

  • ATEX:
    Gas: II 2 G Ex d IIC T6 Gb.
    Dust: II 2 D Ex tb IIIC T85°C Db.
  • IECEX:
    Gas: Ex d IIC T6 Gb.
    Dust: Ex tb IIIC T85°C Db.
  • FM and CSA C-US:
    XP (Explosion-proof): Class I, Division 1, Groups A, B, C, D.
    DIP (Dust-Ignition-proof): Class II/III, Div. 1, Groups E, F, & G.
    Gas: Class I, Zone 1, AEx d IIC T6 Gb.
    Dust: Zone 21, AEx tb IIIC T85°C Db.

Communication

  • Function:Reading display information and reading / writing all configuration settings.
  • Type:RS232, RS485 2-wire Modbus RTU or Local USB.
  • Remote configuration via free downloadable remote configuration tool (see dropdown download above).
  • HART communication is available with the F018 & E018Flow rate Monitor / Totalizers.

 

Downloads

Datasheet: Fluidwell E126-EG Explosion Proof Flowcomputer