Fluidwell F118 Safe area – Flow rate Totalizer

Product Note:

No product notes available.

Description

Fluidwell F118 Safe area – Flow rate Totalizer

Fluidwell F118 Safe area – Flow Rate Totalizer is a versatile flow rate indicator / transmitter and totalizer with the ability to precisely linearize the flowmeter signal. In addition to the average K-Factor or Span, ten linearization points can be entered with their frequencies or values. The unit will interpolate between these points, greatly enhancing accuracy in any flow range, even for very low frequency applications. Moreover, a continuous flow rate monitoring feature is available with high and low flow rate alarm values and up to three alarm outputs.

Flow rate and total are transmitted with an analog and scaled pulse output. The display shows flow rate, total, accumulated total, alarm values, alarm messages and status. On-screen engineering units are easily configured from a comprehensive selection.

Features

  • Ten point linearization of the flow curve – with interpolation.
  • Flow rate monitoring: two alarm values can be set: low and high flow rate alarm.
  • Alarm values can be changed by the operator or they can be password protected.
  • Analog and pulse outputs.
  • Displays total and flow rate simultaneously.
  • Flow rate: seven 8mm (0.31″) digits.
  • Total – resettable: seven 17mm (0.67″) digits.
  • Accumulated total – not resettable: eleven 8mm (0.31″) digits.
  • Separate engineering units for flow rate and total on the display.
  • Up to three configurable alarm or scaled pulse outputs.
  • Displays clear alarm messages.
  • LED backlight.
  • Intrinsically safe according ATEX and IECEx.
  • GRP, Aluminum or high grade stainless steel enclosure.
  • Auto backup of settings and running totals in EEPROM memory.
  • Ambient temperature: -40°C to +80°C (-40°F to 176°F).
  • Various accessories are available for this product.

Applications

  • Liquid flow measurement with mechanic flowmeters where a precise calculation over the full measurement range and continuous flow rate monitoring is required.
  • The F-Series is your first and best choice for field mount indicators in safe and hazardous area applications. Especially in harsh weather conditions like rain, snow, sandy deserts, salty atmospheres and temperatures between -40°C up to +80°C (-40°F up to 176°F).

Specifications

Signal Inputs

Flowmeter Inputs

      • Pulse type inputs:
        Reed-switch, open collector, NAMUR, NPN/PNP pulse, Sine wave (coil), active pulse signal.

Signal Outputs

Pulse outputs

      • Function: Scaled pulse output according to linearized accumulated total (e.g. a pulse every 3.25 gallons).
        Max. frequency: 500Hz.
        Adjustable pulse length from 0.001 sec. to 9.999 seconds.
      • Type: Up to three passive NPN transistors, active PNP transistors or isolated electro-mechanical relays.

Alarm outputs

      • Function: Configurable alarm outputs for low, high or both combined flow rate alarms.
      • Type: Up to three passive NPN transistors, active PNP transistors or isolated electro-mechanical relays.

Analog outputs

      • Function: Re-transmitting the linearized flow rate – the output can be scaled to any range (e.g. 200 L/min to 1200 L/min).
      • Type: One passive isolated, floating or loop powered 4 – 20mA output or one active (0)4 – 20mA or 0 – 10V DC output.

Supply

Power Supply

      • Long life Lithium battery.
      • 4 – 20mA Loop-powered.
      • 8 – 24V AC/DC.
      • 115 – 230V AC.
      • Basic: 8 – 30V DC.

Sensor Supply

      • 3.2, 8.2, 12, 24V DC.

Hazardous Area

Intrinsically Safe

      • ATEX:
        Gas: II 1 G Ex ia IIB/IIC T4 Ga
        Dust: II 1 D Ex ia IIIC T200 100 °C Da
      • IECEx:
        Gas: Ex ia IIC/IIB T4 Ga
        Dust: Ex ia IIIC T200 100 °C Da

Explosion Proof

      • ATEX:
        Gas: II 2 G / Ex d IIB T5 Gb
        Dust: II 2 D / Ex t IIIB T100°C Db

Communication

      • Function: All process data and settings can be read and modified through the communication link.
      • Protocol: Modbus RTU.
      • Interface: RS232 / RS485 2-wire or 4-wire / TTL.
      • HART communication is available with the F018 & E018 Flow rate Monitor / Totalizers.

 

Downloads

Datasheet: Fluidwell F118 Safe area Intrinsically safe – Flow rate Totalizer

Related Products

Fluidwell F118 Safe area – Flow rate Totalizer

Fluidwell F118 Safe area – Flow Rate Totalizer is a versatile flow rate indicator / transmitter and totalizer with the ability to precisely linearize the flowmeter signal.

Product Note:

No product notes available.

Loading...

Description

Fluidwell F118 Safe area – Flow rate Totalizer

Fluidwell F118 Safe area – Flow Rate Totalizer is a versatile flow rate indicator / transmitter and totalizer with the ability to precisely linearize the flowmeter signal. In addition to the average K-Factor or Span, ten linearization points can be entered with their frequencies or values. The unit will interpolate between these points, greatly enhancing accuracy in any flow range, even for very low frequency applications. Moreover, a continuous flow rate monitoring feature is available with high and low flow rate alarm values and up to three alarm outputs.

Flow rate and total are transmitted with an analog and scaled pulse output. The display shows flow rate, total, accumulated total, alarm values, alarm messages and status. On-screen engineering units are easily configured from a comprehensive selection.

Features

  • Ten point linearization of the flow curve – with interpolation.
  • Flow rate monitoring: two alarm values can be set: low and high flow rate alarm.
  • Alarm values can be changed by the operator or they can be password protected.
  • Analog and pulse outputs.
  • Displays total and flow rate simultaneously.
  • Flow rate: seven 8mm (0.31″) digits.
  • Total – resettable: seven 17mm (0.67″) digits.
  • Accumulated total – not resettable: eleven 8mm (0.31″) digits.
  • Separate engineering units for flow rate and total on the display.
  • Up to three configurable alarm or scaled pulse outputs.
  • Displays clear alarm messages.
  • LED backlight.
  • Intrinsically safe according ATEX and IECEx.
  • GRP, Aluminum or high grade stainless steel enclosure.
  • Auto backup of settings and running totals in EEPROM memory.
  • Ambient temperature: -40°C to +80°C (-40°F to 176°F).
  • Various accessories are available for this product.

Applications

  • Liquid flow measurement with mechanic flowmeters where a precise calculation over the full measurement range and continuous flow rate monitoring is required.
  • The F-Series is your first and best choice for field mount indicators in safe and hazardous area applications. Especially in harsh weather conditions like rain, snow, sandy deserts, salty atmospheres and temperatures between -40°C up to +80°C (-40°F up to 176°F).

Specifications

Signal Inputs

Flowmeter Inputs

      • Pulse type inputs:
        Reed-switch, open collector, NAMUR, NPN/PNP pulse, Sine wave (coil), active pulse signal.

Signal Outputs

Pulse outputs

      • Function: Scaled pulse output according to linearized accumulated total (e.g. a pulse every 3.25 gallons).
        Max. frequency: 500Hz.
        Adjustable pulse length from 0.001 sec. to 9.999 seconds.
      • Type: Up to three passive NPN transistors, active PNP transistors or isolated electro-mechanical relays.

Alarm outputs

      • Function: Configurable alarm outputs for low, high or both combined flow rate alarms.
      • Type: Up to three passive NPN transistors, active PNP transistors or isolated electro-mechanical relays.

Analog outputs

      • Function: Re-transmitting the linearized flow rate – the output can be scaled to any range (e.g. 200 L/min to 1200 L/min).
      • Type: One passive isolated, floating or loop powered 4 – 20mA output or one active (0)4 – 20mA or 0 – 10V DC output.

Supply

Power Supply

      • Long life Lithium battery.
      • 4 – 20mA Loop-powered.
      • 8 – 24V AC/DC.
      • 115 – 230V AC.
      • Basic: 8 – 30V DC.

Sensor Supply

      • 3.2, 8.2, 12, 24V DC.

Hazardous Area

Intrinsically Safe

      • ATEX:
        Gas: II 1 G Ex ia IIB/IIC T4 Ga
        Dust: II 1 D Ex ia IIIC T200 100 °C Da
      • IECEx:
        Gas: Ex ia IIC/IIB T4 Ga
        Dust: Ex ia IIIC T200 100 °C Da

Explosion Proof

      • ATEX:
        Gas: II 2 G / Ex d IIB T5 Gb
        Dust: II 2 D / Ex t IIIB T100°C Db

Communication

      • Function: All process data and settings can be read and modified through the communication link.
      • Protocol: Modbus RTU.
      • Interface: RS232 / RS485 2-wire or 4-wire / TTL.
      • HART communication is available with the F018 & E018 Flow rate Monitor / Totalizers.

 

Downloads

Datasheet: Fluidwell F118 Safe area Intrinsically safe – Flow rate Totalizer