onoae

Gastec WP-133 Waste Water Test Kit

Product Note:

No product notes available.

Categories: , Tags: , ,

Description

Gastec WP-133 Waste Water Test Kit

Gastec WP-133 Waste Water Test Kit Enables concentrations of organic chlorinated solvents (e.g. tetrachloroethylene, trichloroethylene) present in wastewater to be easily measured.

*We also have the Waste water test kit WPT-132 / WPT-133 / WPT-135 which includes the Gas sampling pump GV-100 instead of the Plastic syringe pump.

How to use:

  1. Measure 200mL of wastewater with the beaker, replace it in the glass jar, seal the opening with a stopper, and shake it for one minute.
  2. Both ends of the detector tube are broken off, and it is inserted in the syringe or sampling pump (GV-100) for gas sampling.
  3. The stopper of the glass jar is removed, and measurement is done with the point of the detector tube just above the surface of the liquid.
  4. After the measuring time is over, the scale on the detector tube is read.
  5. The temperature of the wastewater is measured.
  6. By using the conversion data of the user manual, calculate the concentration in the wastewater.

 

 

Features

  • Enables concentrations of organic chlorinated solvents present in wastewater to be easily measured.

Applications

  • Measure 200mL of wastewater with the beaker, replace it in the glass jar, seal the opening with a stopper, and shake it for one minute.
  • Both ends of the detector tube are broken off, and it is inserted in the syringe or sampling pump (GV-100) for gas sampling.
  • The stopper of the glass jar is removed, and measurement is done with the point of the detector tube just above the surface of the liquid.
  • After the measuring time is over, the scale on the detector tube is read.
  • The temperature of the wastewater is measured.
  • By using the conversion data of the user manual, calculate the concentration in the wastewater.

Specifications

Substance to be measuredTube No. & NameMeasuring range
Trichloroethylene132MTrichloroethylene0.14 – 7.0 mg/l
132LLTrichloroethylene0.007 – 0.256 mg/l
132LTrichloroethylene0.056 – 1.95 mg/l
132LCTrichloroethylene0.1 – 0.4 mg/l
Tetrachloroethylene133MTetrachloroethylene0.13 – 6.3 mg/l
133LLTetrachloroethylene0.005 – 0.174 mg/l
133LTetrachloroethylene0.052 – 1.93 mg/l
133LCTetrachloroethylene0.05 – 0.3 mg/l
1,1,1-Trichloroethane135L1,1,1-Trichloroethane0.4 – 14 mg/l

Downloads

Related Products

Gastec WP-133 Waste Water Test Kit

Gastec WP-133 Waste Water Test Kit Enables concentrations of organic chlorinated solvents (e.g. tetrachloroethylene, trichloroethylene) present in wastewater to be easily measured.

Product Note:

No product notes available.

Categories: , Tags: , ,

Loading...

Description

Gastec WP-133 Waste Water Test Kit

Gastec WP-133 Waste Water Test Kit Enables concentrations of organic chlorinated solvents (e.g. tetrachloroethylene, trichloroethylene) present in wastewater to be easily measured.

*We also have the Waste water test kit WPT-132 / WPT-133 / WPT-135 which includes the Gas sampling pump GV-100 instead of the Plastic syringe pump.

How to use:

  1. Measure 200mL of wastewater with the beaker, replace it in the glass jar, seal the opening with a stopper, and shake it for one minute.
  2. Both ends of the detector tube are broken off, and it is inserted in the syringe or sampling pump (GV-100) for gas sampling.
  3. The stopper of the glass jar is removed, and measurement is done with the point of the detector tube just above the surface of the liquid.
  4. After the measuring time is over, the scale on the detector tube is read.
  5. The temperature of the wastewater is measured.
  6. By using the conversion data of the user manual, calculate the concentration in the wastewater.

 

 

Features

  • Enables concentrations of organic chlorinated solvents present in wastewater to be easily measured.

Applications

  • Measure 200mL of wastewater with the beaker, replace it in the glass jar, seal the opening with a stopper, and shake it for one minute.
  • Both ends of the detector tube are broken off, and it is inserted in the syringe or sampling pump (GV-100) for gas sampling.
  • The stopper of the glass jar is removed, and measurement is done with the point of the detector tube just above the surface of the liquid.
  • After the measuring time is over, the scale on the detector tube is read.
  • The temperature of the wastewater is measured.
  • By using the conversion data of the user manual, calculate the concentration in the wastewater.

Specifications

Substance to be measuredTube No. & NameMeasuring range
Trichloroethylene132MTrichloroethylene0.14 – 7.0 mg/l
132LLTrichloroethylene0.007 – 0.256 mg/l
132LTrichloroethylene0.056 – 1.95 mg/l
132LCTrichloroethylene0.1 – 0.4 mg/l
Tetrachloroethylene133MTetrachloroethylene0.13 – 6.3 mg/l
133LLTetrachloroethylene0.005 – 0.174 mg/l
133LTetrachloroethylene0.052 – 1.93 mg/l
133LCTetrachloroethylene0.05 – 0.3 mg/l
1,1,1-Trichloroethane135L1,1,1-Trichloroethane0.4 – 14 mg/l

Downloads