Display Monitor SA22-FC001-DP012-OW03 For Mark II XG Diesel Controller

The SA22-FC001-DP012-OW03 Display Monitor is a display component specifically designed for use with the Mark II XG Diesel Engine Fire Pump Controller. This monitor provides a visual interface that allows users to monitor and control fire pump operations more efficiently.

Features

  • 128×64 Pixel Backlit LCD Display: Clearly displays operational information, including motor status, alarms, events, and pressure conditions.
  • User Interface with Keypad: Allows easy navigation of menus and system parameter settings.
  • LED Indicators: Provides visual indication of various statuses such as AC power availability, active alarms, operating modes, and other system conditions.
  • USB Host Port: Facilitates storage and transfer of log data and system configuration via an external USB device.
  • Durable Design: Built to meet NEMA Type 2, 3R, 4, 4X, and 12 standards, ensuring protection against various environmental conditions.

Applications

This monitor is designed for integration with the Mark II XG Diesel Engine Fire Pump Controller, which is used in fire fighting systems to:

  • Monitor and record fire pump operational information.
  • Display real-time system status and alarms.
  • Facilitate setting and controlling operational parameters through an intuitive user interface.

Specification

  • Screen Resolution: 128 x 64 pixels
  • Screen Type: LCD with backlit
  • User Interface: Membrane keypad with navigation keys
  • Communication Port: USB Host for external device connectivity
    • LED Indicators:
    • AC Power Available
    • Alarm
    • Main Switch in Auto
    • Main Switch in Manual
    • Low System Pressure
    • Engine Running
    • Engine Start Failure
    • High Engine Temperature
    • Low Engine Oil Pressure
    • Engine Overspeed
    • Engine Alternative ECM
    • Engine Fuel Injector Malfunction
    • Low Fuel Level
    • Automatic Shutdown Disabled
    • Charger Malfunction
    • Battery Problem #1
    • Battery Problem #2
  • Protection Standards: NEMA Type 2, 3R, 4, 4X, and 12

Reviews

There are no reviews yet.

Only logged in customers who have purchased this product may leave a review.

Related Products

Sale!

Display Monitor SA22-FC001-DP012-OW03 For Mark II XG Diesel Controller

The SA22-FC001-DP012-OW03 Display Monitor is a display component specifically designed for use with the Mark II XG Diesel Engine Fire Pump Controller.

Minimum Order: 1 units

Lead Time: 8 weeks

Product Note:

No product notes available.

Original price was: Rp 64.500.000.Current price is: Rp 63.546.000.

Available on backorder

Loading...

Description

Display Monitor SA22-FC001-DP012-OW03 For Mark II XG Diesel Controller

The SA22-FC001-DP012-OW03 Display Monitor is a display component specifically designed for use with the Mark II XG Diesel Engine Fire Pump Controller. This monitor provides a visual interface that allows users to monitor and control fire pump operations more efficiently.

Features

  • 128×64 Pixel Backlit LCD Display: Clearly displays operational information, including motor status, alarms, events, and pressure conditions.
  • User Interface with Keypad: Allows easy navigation of menus and system parameter settings.
  • LED Indicators: Provides visual indication of various statuses such as AC power availability, active alarms, operating modes, and other system conditions.
  • USB Host Port: Facilitates storage and transfer of log data and system configuration via an external USB device.
  • Durable Design: Built to meet NEMA Type 2, 3R, 4, 4X, and 12 standards, ensuring protection against various environmental conditions.

Applications

This monitor is designed for integration with the Mark II XG Diesel Engine Fire Pump Controller, which is used in fire fighting systems to:

  • Monitor and record fire pump operational information.
  • Display real-time system status and alarms.
  • Facilitate setting and controlling operational parameters through an intuitive user interface.

Specification

  • Screen Resolution: 128 x 64 pixels
  • Screen Type: LCD with backlit
  • User Interface: Membrane keypad with navigation keys
  • Communication Port: USB Host for external device connectivity
    • LED Indicators:
    • AC Power Available
    • Alarm
    • Main Switch in Auto
    • Main Switch in Manual
    • Low System Pressure
    • Engine Running
    • Engine Start Failure
    • High Engine Temperature
    • Low Engine Oil Pressure
    • Engine Overspeed
    • Engine Alternative ECM
    • Engine Fuel Injector Malfunction
    • Low Fuel Level
    • Automatic Shutdown Disabled
    • Charger Malfunction
    • Battery Problem #1
    • Battery Problem #2
  • Protection Standards: NEMA Type 2, 3R, 4, 4X, and 12