Nominal Flow (Qₙₒₘ)* |
300 kg/min (661.4 lb/min) |
Maximum Flow (Qₘₐₓ)* |
300 kg/min (661.4 lb/min) |
Typical Minimum Flow (Qₘᵢₙ)* |
3 kg/min (6.6 lb/min) |
Serial Tube / Single Path |
Flow rates Qmax, Qnom and Qmin for “serial” sensors will be 50% of the above listed parallel/dual path version. |
Operating Temperature |
Fluid temperature range options cover applications from -196°C to 350°C (-320°F to 662°F). |
Ambient Temperature |
-50 °C to +80 °C (-60 °F to +180 °F) (standard), versions available for installation in vacuum chamber (-260 °C / -430 °F) or oven (up to +210 °C / +410 °F) (optional) |
Pressure Ratings |
Up to 1379 bar / 20000 psi – dependent upon material |
Electrical Connection Sensor
w/o Integral Transmitter |
M20 x 1.5 standard cable entry for JM, SM terminal box versions
Optional entries available: ½” NPT or M25 x 1.5 (only for SM) or ¾″ NPT (only for SM)
M16 x 1.5 standard cable entry for PM terminal box version
Max. cable length to remote RHE transmitter 100 m/330 ft |
Sensor Enclosure Materials |
Stainless steel 304 (standard), SS 316 (optional)
Coated aluminum terminal box, SS 316 terminal box (optional) |
Enclosure Type |
Protection class IP66, NEMA 4X (standard), IP66/67, NEMA 4X/6 (optional) |
Wetted Materials |
Flow tubes SS 316Ti, Alloy C22, Tantalum or SuperDuplex
Manifolds SS 316L; Seal material (manifold construction): PTFE
Standard flanges SS 316Ti, other connections SS 316L
Additional/customer specific materials available upon request |
Process Connections |
Nearly any – the Rheonik AnyPipeFit Commitment. Consult factory for types/sizes not listed in this data sheet on the Mechanical Construction pages |
Pressure Rating Compliance |
Europe – PED: Sound Engineering Practice (SEP), Module A2, Module B3.1+C2
Canada – CRN: Canadian Registration Number |
Certifications and Approvals |
ATEX / IECEx Approvals for Zone 0, 1 (details see page 17)
North American Approvals Class I, Div. 1, 2, Gr. A,B,C,D, Zone 0, 1
American Bureau of Shipping (ABS) Product Type Approval for use on marine vessels |
Testing and Inspection |
All sensors are hydro tested, calibrated and supplied with a traceable calibration certificate. Customized calibration and testing services are available |
Project Documentation and QA, Services |
Rheonik offers a full set of services for large and complex engineering projects.
Typical services offered are, but not limited to:•Certificates of origin and conformity, mill certificates
•Data books including WPAR, WQS, NDT, test & quality plans, functional testing, calibration procedures, customized packing, factory acceptance etc.
•Painting to project specification
•Start up and commissioning services on/offshore |
Options |
Enclosure heating for high temperature applications
Cleaning for oxygen service , …
For more consult factory |