onoae

Rheonik RHM20 Coriolis Mass Flow Meter

Rheonik RHM20 Coriolis Mass Flow Meter is designed for general-purpose flow measurement without the need for maintenance. Robust and accurate, the RHM 20 outperforms other flow technologies at an attractively low cost of ownership.

Rheonik RHM20 Coriolis Mass Flow Meter is designed for general-purpose flow measurement without the need for maintenance. Robust and accurate, the RHM 20 outperforms other flow technologies at an attractively low cost of ownership.

  • Range: 1 kg/min up to 480 kg/min
  • Pressure: up to 345 bar (5003 psi)
  • Temperature: -196°C (-321°F) up to +350°C (662°F)
  • Accuracy: 0.1 % of rate
  • Materials: SS 316L / SS 316Ti, Alloy C22 – 2.4602, Tantalum – UNS R05200, Super Duplex – 1.4410
  • Process Connection: ¾” up to 2 ½”

Features

  • Typical measuring range up to 300 kg/min (661.39 lb/min)
  • Pressure ratings up to 586 bar (8499 psi)
  • Temperature ratings from -196 to +350 °C (-320 to +662°F) – extended on request
  • Mass flow uncertainty down to 0.05%
  • Repeatability down to 0.05 %
  • 4 kHz measurement updates and response time of less than 10 ms when used with RHE 40 Series transmitters
  • Accurately measure flow rates down to 3 kg/min
  • The Rheonik AnyPipeFit Commitment provides custom process connection type and size flexibility on any meter to suit your existing plant, saving time and expense on installation costs
  • Compact design with minimal pipeline footprint
  • Approved for use in hazardous areas
  • SS 304 Stainless steel enclosure, SS 316 optional
  • Integral and remote transmitter versions available

Applications

  • Medium Size Sensors
  • Chemical Injection
  • Fuel Consumption
  • Oil Measurement
  • Plastics Production

Specifications

Nominal Flow (Q)* 300 kg/min (661.4 lb/min)
Maximum Flow (Qₘₐₓ)* 300 kg/min (661.4 lb/min)
Typical Minimum Flow (Qₘᵢₙ)* 3 kg/min (6.6 lb/min)
Serial Tube / Single Path Flow rates Qmax, Qnom and Qmin for “serial” sensors will be 50% of the above listed parallel/dual path version.
Operating Temperature Fluid temperature range options cover applications from -196°C to 350°C (-320°F to 662°F).
Ambient Temperature -50 °C to +80 °C (-60 °F to +180 °F) (standard), versions available for installation in vacuum chamber (-260 °C / -430 °F) or oven (up to +210 °C / +410 °F) (optional)
Pressure Ratings Up to 1379 bar / 20000 psi – dependent upon material
Electrical Connection Sensor
w/o Integral Transmitter
M20 x 1.5 standard cable entry for JM, SM terminal box versions

Optional entries available: ½” NPT or M25 x 1.5 (only for SM) or ¾″ NPT (only for SM)

M16 x 1.5 standard cable entry for PM terminal box version

Max. cable length to remote RHE transmitter 100 m/330 ft

Sensor Enclosure Materials Stainless steel 304 (standard), SS 316 (optional)

Coated aluminum terminal box, SS 316 terminal box (optional)

Enclosure Type Protection class IP66, NEMA 4X (standard), IP66/67, NEMA 4X/6 (optional)
Wetted Materials Flow tubes SS 316Ti, Alloy C22, Tantalum or SuperDuplex

Manifolds SS 316L; Seal material (manifold construction): PTFE

Standard flanges SS 316Ti, other connections SS 316L

Additional/customer specific materials available upon request

Process Connections Nearly any – the Rheonik AnyPipeFit Commitment.  Consult factory for types/sizes not listed in this data sheet on the Mechanical Construction pages
Pressure Rating Compliance Europe – PED: Sound Engineering Practice (SEP), Module A2, Module B3.1+C2

Canada – CRN: Canadian Registration Number

Certifications and Approvals ATEX / IECEx Approvals for Zone 0, 1 (details see page 17)

North American Approvals Class I, Div. 1, 2, Gr. A,B,C,D, Zone 0, 1

American Bureau of Shipping (ABS) Product Type Approval for use on marine vessels

Testing and Inspection All sensors are hydro tested, calibrated and supplied with a traceable calibration certificate. Customized calibration and testing services are available
Project Documentation and QA, Services Rheonik offers a full set of services for large and complex engineering projects.
Typical services offered are, but not limited to:•Certificates of origin and conformity, mill certificates

•Data books including WPAR, WQS, NDT, test & quality plans, functional testing, calibration procedures, customized packing, factory acceptance etc.

•Painting to project specification

•Start up and commissioning services on/offshore

Options Enclosure heating for high temperature applications

Cleaning for oxygen service , …

For more consult factory

Downloads

Rheonik RHM20 Coriolis Mass Flow Meter

Shopping Cart